6. Random Access Adjustment Mode
6.5.9.3 Fine Vertical Linearity
How to adjust the Fine Vertical Linearity?
1. Push the
↑
or
↓
keys to highlight
Fine V Linearity
and press
ENTER
to select.
LINEARITY
COARSE LINEARITY
FINE V LINEARITY
FINE H LINEARITY
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 6-57
A selection area menu will be displayed.
2. Push the
↑
or
↓
keys to select one of the 9 possible areas and press
ENTER
to confirm.
1
2
3
4
5
6
7
8
9
Image 6-32
Fine Vertical Linearity
3. Use the cursor keys to correct the Vertical Linearity of the image in this specific area.
4. Press
ENTER
to save the correction and to return to the selection screen.
5. Repeat step 2 till 4 for each area that needs an adjustment.
6. Press
EXIT
to return to the
Linearity
menu.
6.5.9.4 Fine Horizontal Linearity
How to adjust the Fine Horizontal Linearity?
1. Push the
↑
or
↓
keys to highlight
Fine H Linearity
and press
ENTER
to select.
LINEARITY
COARSE LINEARITY
FINE V LINEARITY
FINE H LINEARITY
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 6-58
2. Push the
↑
or
↓
keys to select one of the 9 possible areas and press
ENTER
to confirm.
R5976398 BARCOREALITY 909 SPLIT PACK 21/02/2003
59
Summary of Contents for BarcoReality 909 Split Pack R9040040
Page 1: ...BarcoReality 909 Split Pack Owner s Manual R9040040 R5976398 01 21 02 2003 ...
Page 4: ......
Page 8: ...Table of contents 4 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 12: ...1 Safety Instructions 8 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 14: ...2 AC Power 10 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 104: ...7 Service Mode 100 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 110: ...Index 106 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...