7. Service Mode
7.7 Voltage Diagnostics
What can be seen?
The numeric value of the different voltages will be displayed in real time in the
Voltage Diagnostics
menu.
How to start up Voltage Diagnostics?
1. Push the
↑
or
↓
keys to highlight
Voltage Diagnostics
and press
ENTER
to select.
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
VOLTAGE DIAGNOSTICS
PROJECTOR DIAGNOSTICS
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 7-71
The
Voltage Diagnostics
menu will be displayed.
VOLTAGE DIAGNOSTICS
+17V:
+16.9 Volt
-17V:
-17.1 Volt
+9V:
+9 Volt
+12V:
+11.9 Volt
-12V:
-11.8 Volt
+30V:
+29.8 Volt
-40V:
-39.8 Volt
+110V:
+110 Volt
+210V:
+209 Volt
HTHD:
+124.5 Volt
-conv:
-32.4 Volt
+conv:
+33.1 Volt
foc_lo: +28.8 Volt
foc_hi: +41.3 Volt
<EXIT> to return.
Menu 7-72
7.8 Projector Diagnostics
What can be seen?
A log of the last 5 events including the run time when the event happened can be consulted in the Projector Diagnostics.
How to start up Projector Diagnostics?
1. Push the
↑
or
↓
keys to highlight
Projector Diagnostics
and press
ENTER
to select.
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
VOLTAGE DIAGNOSTICS
PROJECTOR DIAGNOSTICS
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 7-73
98
R5976398 BARCOREALITY 909 SPLIT PACK 21/02/2003
Summary of Contents for BarcoReality 909 Split Pack R9040040
Page 1: ...BarcoReality 909 Split Pack Owner s Manual R9040040 R5976398 01 21 02 2003 ...
Page 4: ......
Page 8: ...Table of contents 4 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 12: ...1 Safety Instructions 8 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 14: ...2 AC Power 10 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 104: ...7 Service Mode 100 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...
Page 110: ...Index 106 R5976398 BARCOREALITY 909 SPLIT PACK 21 02 2003 ...