3. Replacing the Analyzers
3. REPLACING THE ANALYZERS
Overview
•
•
3.1 Removing the Analyzers
Necessary tools
•
flat screwdriver
•
Philips screwdriver
How to remove the analyzers ?
1. Remove the power cable (1) (image 3-1)
2. Remove the flat cables (2), disconnect by simultaneously pulling out the 2 mini locks on both sides of the flat cable connector.
Caution:
Do not touch the contacts of the flat cable when removing the flat cable otherwise damage my occur by oxidation of
these contacts.
Do not use any tools when (dis)connecting a flat cable connector, otherwise damage may occur on the mini locks.
3. Loosen the 4 screws and remove the buffer module (image 3-2)
4. Loosen the 3 screws and remove the metallic plate (image 3-3)
5. Remove the analyzer by pulling it slightly laterally to free fixation holes and sliding it gently out of the assembly. One may use a
screwdriver to pull out the analyzer (by putting it in the screwdriver opening) (image 3-4)
Image 3-1
Image 3-2
Image 3-3
R5976046 ANALYSER KIT FOR R/G 6300/6400 AND SIM6 01122003