Service mode
6 - 24
5976419 BARON 908 04122001
The I2C address, IC number and module name will be given in I2C diagnostic menu.
When no errors are detected, the following message will appear on the screen :
"No errors on i2c-bus detected".
How to select ?
1. Push the cursor key
é
or
ê
to highlight 'I²C Diagnostics' (menu 1).
2. Press
ENTER
to display the diagnostic menu (menu 2).
Voltage diagnostics
What can be seen ?
The numeric value of the different voltages will be displayed in real time on the voltage diagnostics menu.
How to start up ?
1. Push the cursor key
é
or
ê
to highlight 'Voltage diagnostics' (menu 1).
2. Press
ENTER
to display the voltage diagnostic menu (menu 2).
Scroll with or
then <ENTER>
<EXIT> to return.
I2C DIAGNOSTICS
Failures :
addr IC number mod.name
48H
IC200
DECODER
menu 2
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
SERVICE MODE
menu 1
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
VOLTAGE DIAGNOSTICS
PROJECTOR DIAGNOSTICS
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
SERVICE MODE
menu 1
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
VOLTAGE DIAGNOSTICS
PROJECTOR DIAGNOSTICS
<EXIT> to return.
VOLTAGE DIAGNOSTICS
menu 2
+17V :
16.9 Volt
-17V :
-17.1 Volt
+9V
:
+9 Volt
+12V :
+11.9 Volt
-12V :
-11.8 Volt
+30V :
+29.8 Volt
-40V :
-39.8 Volt
+110V :
+110 Volt
+210V :
+209 Volt
HTHD :
+124.5 Volt
-conv :
-32.4 Volt
+conv :
+33.1 Volt
foc_lo :
+28.8 Volt
foc_hi :
+41.3 Volt
I2C Diagnostics
What can be seen ?
The I2C diagnostics menu gives an overview of the I2C failures inside the projector.
To scroll through the failure list, push the cursor key
é
or
ê
.
Summary of Contents for Baron 908 R9040060
Page 1: ...BARON 908 R9040060 R9040069 OWNER S MANUAL ...
Page 2: ......
Page 12: ...Table of contents 0 8 5976419 BARON 908 04122001 ...
Page 22: ...Connections 2 6 5976419 BARON 908 15032003 ...
Page 30: ...Getting started 3 8 5976419 BARON 908 04122001 ...
Page 94: ...Servicemode 6 26 5976419 BARON 908 04122001 ...