Date: 15/05/2000
Replacement of a picture tube
Cine
7
3
R9002380
R9002389
B. Electrical disconnection
4. EHT lead disconnection
Pull out the EHT lead of the defective picture tube from the EHT splitter.
5. Picture tube drive module removal (see picture above)
Disconnect the ground connection of the neck screening
(A) by separating male from the female bullet terminal (B).
Disconnect the CRT ground plug (C) of the defective
picture tube.
Disconnect ground connection (D) of the CRT drive module
by removing screw (E) on main frame.
Loosen the gear clamp of the Picture tube drive module
(F).
Carefully pull the module (D) back to slide the CRT socket
off from the end of the CRT.
Important:
Deflection Unit can be slid off from the CRT
neck after the picture tube has been mechanical discon-
nected from main frame. Therefore, electrical disconnec-
tion of the deflection block is not necessary.
EHT lead
Red Green Blue
To pull out
To open
To secure
B
A
EHT lead
C
C
F
E
D
Drive module removed