E. Troubleshooting
E. TROUBLESHOOTING
E.1 Error codes
Overview
When the error code is preceded by a ’-’ sign, then the error means a real error for the projector.
When the error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
code
Description
Error
Warning
Caused by
Action
1001
Wrong lamp 1
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1002
Wrong lamp 2
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1003
Wrong lamp 3
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1004
Wrong lamp 4
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1011
Lamp 1 missing
Yes
Yes
No lamp inserted in position 1
Insert a lamp in position 1
1012
Lamp 2 missing
Yes
Yes
No lamp inserted in position 2
Insert a lamp in position 2
1013
Lamp 3 missing
Yes
Yes
No lamp inserted in position 3
Insert a lamp in position 3
1014
Lamp 4 missing
Yes
Yes
No lamp inserted in position 4
Insert a lamp in position 4
1021
Lamp 1 broken
Yes
-
Lamp 1 is not ON
Check installation of lamp 1
(connection, cable, etc.)
1022
Lamp 2 broken
Yes
-
Lamp 2 is not ON
Check installation of lamp 2
(connection, cable, etc.)
1023
Lamp 3 broken
Yes
-
Lamp 3 is not ON
Check installation of lamp 3
(connection, cable, etc.)
1024
Lamp 4 broken
Yes
-
Lamp 4 is not ON
Check installation of lamp 4
(connection, cable, etc.)
1399
I²C open error
Yes
1398
I²C read error
Yes
1397
I²C write error
Yes
1699
Formatter busy
1697
Formatter init
failed
Yes
-
no communication with formatter
ctrl
Call a quali
fi
ed service engineer
1696
Formatter ctrl
init failed
Yes
-
no communication with formatter
ctrl
Call a quali
fi
ed service engineer
1695
Formatter start
failed
Yes
-
no communication with formatter
Call a quali
fi
ed service engineer
1693
1692
1691
2100
LPS 1 error
Yes
-
Replace LPS
2400
LPS 2 error
Yes
-
Replace LPS
2700
LPS 3 error
Yes
-
Replace LPS
3000
LPS 4 error
Yes
-
Replace LPS
R59770021 CLM R10+ 11/10/2010
203
Summary of Contents for CLM R10+
Page 1: ...CLM R10 Users manual R9050100 R90501001 R90501005 R59770021 11 11 10 2010 ...
Page 14: ...1 Safety 10 R59770021 CLM R10 11 10 2010 ...
Page 22: ...2 General 18 R59770021 CLM R10 11 10 2010 ...
Page 36: ...3 Physical installation 32 R59770021 CLM R10 11 10 2010 ...
Page 41: ...4 Stacking CLM projectors Zoom Image 4 9 Zoom adjustment R59770021 CLM R10 11 10 2010 37 ...
Page 42: ...4 Stacking CLM projectors 38 R59770021 CLM R10 11 10 2010 ...
Page 50: ...5 Connections 46 R59770021 CLM R10 11 10 2010 ...
Page 66: ...7 Start up of the Adjustment mode 62 R59770021 CLM R10 11 10 2010 ...
Page 75: ...8 Input menu Image 8 26 Image 8 27 Image 8 28 R59770021 CLM R10 11 10 2010 71 ...
Page 76: ...8 Input menu 72 R59770021 CLM R10 11 10 2010 ...
Page 102: ...9 Image menu 98 R59770021 CLM R10 11 10 2010 ...
Page 169: ...14 Service menu Image 14 55 Image 14 56 Image 14 57 R59770021 CLM R10 11 10 2010 165 ...
Page 170: ...14 Service menu 166 R59770021 CLM R10 11 10 2010 ...
Page 184: ...16 Servicing 180 R59770021 CLM R10 11 10 2010 ...
Page 194: ...17 Projector covers removal and installation 190 R59770021 CLM R10 11 10 2010 ...
Page 202: ...C DMX Chart 198 R59770021 CLM R10 11 10 2010 ...
Page 212: ...E Troubleshooting 208 R59770021 CLM R10 11 10 2010 ...
Page 218: ...F Mounting optional Carry handle 214 R59770021 CLM R10 11 10 2010 ...
Page 220: ...G Order info 216 R59770021 CLM R10 11 10 2010 ...