4. Physical installation projector
Necessary parts
•
(for 3W+N+PE, 230/400V) Certi
fi
ed power cable, minimum 4 mm² or AWG 10, 500V rated, cable diameter between 11 mm and
21 mm or
•
(for 3W+PE, 208V) Certi
fi
ed power cable, minimum 4 mm² or AWG 10, 300V rated, cable diameter between 11 mm and 21 mm
•
Circuit breaker maximum 40A
How to connect
1. Remove the back cover.
2. Remove the power input cover.
3. Loosen the cable gland
fi
xation ring (1).
Note:
The cable gland (1) is speci
fi
ed for cables with a diameter between 11mm and 21mm.
1
Image 4-12
Power cable connection
4. Push the stripped power supply cable through the cable gland. When using a
fl
exible power cord, make sure that each conductor
end is provided with an end sleeve.
Fix the cable in the cable gland by securing ring 1 with an adjustable wrench.
5. Connect the power cord with the terminal barrier strip. Use a
fl
at torque screw driver set to
1.4 Nm
.
Always connect the ground wire (PE) with the connector indicated with
PE
on the terminal barrier strip.
If a neutral conductor is available, connect always to the connector indicated with
N
on the terminal barrier strip
Warning:
Always connect
fi
rst the PE wire.
3W+N+PE
3W + PE
L1
L2
L3
N
PE
L1
L2
L3
PE
Image 4-13
Terminal connections
6. Reinstall the power connection cover.
R5906753 DPXK BLP SERIES 20/11/2017
33
Summary of Contents for DP2K-17BLP
Page 4: ......
Page 8: ...Table of contents 4 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 30: ...3 Installation process 26 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 40: ...4 Physical installation projector 36 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 120: ...10 Communicator Touch Panel Image 10 7 Connections 116 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 152: ...14 Maintenance 148 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 162: ...16 Color calibration 158 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 176: ...18 Specifications 172 R5906753 DPXK BLP SERIES 20 11 2017 ...