12. Color calibration
In
fl
uence of aspect ratio
The aspect ratio of the projected image could have a small in
fl
uence upon the measured xy coordinates. Therefore, it’s recom-
mended to save the xy coordinates per aspect ratio in separate MCGD
fi
les.
Color gamut calibration procedure:
1.
Setup the ambient light conditions
as it should be during the play out of the movie. (e.g. only the stairs and emergency exit
lighting is switched on).
Note:
In an optimal setup less than 1% of light from any other source than the light from the projector should illuminate the
screen.
2.
Sequentially measure and enter the xy coordinates
of the three primary colors (red, green, blue) and full white. Use therefore
the Communicator. Go to
Installation
>
Color calibration
>
Measure native colors
. For detailed instructions see user guide of the
Communicator.
Caution:
Ensure that the correct projection mode is selected: 2D or External 3D.
Caution:
In case of 3D, measure the xy coordinates once through the left eye glass of the 3D goggles and once through the
right eye glass.
Tip:
When using the wizard for white point calibration you can immediately proceed with the electronic correction.
3. Once all xy coordinates are measured and entered proceed by saving all measured values into a MCGD
fi
le.
Tip:
Put in the MCGD
fi
le name the type of projection mode (2D or External 3D) and the aspect ratio (FLAT, SCOPE).
4. Map the MCGD
fi
le with the TCGD
fi
le. Use for that the Communicator. Go to
Installation
>
Color calibration
>
Select target
colors
. For detailed instructions see user guide of the Communicator.
5. In addition you can check if the corrected colors complies. Use therefore the Communicator. Go to
Installation
>
Color calibration
>
Verify corrected colors
. For detailed instructions see user guide of the Communicator.
116
R5906847 DP2K SLP SERIES 02/06/2017
Summary of Contents for DP2K SLP Series
Page 1: ...DP2K SLP Series User and Installation manual R5906847 00 02 06 2017 ...
Page 4: ......
Page 15: ...1 Safety PR RESTRICTED AREA RESTRICTED AREA Image 1 2 R5906847 DP2K SLP SERIES 02 06 2017 11 ...
Page 18: ...1 Safety 14 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 44: ...5 Lenses Lens selection 40 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 86: ...7 ICMP 82 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 96: ...9 Starting up 92 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 108: ...10 Scheimpflug 104 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 116: ...11 Convergence 112 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 124: ...13 Preventative maintenance actions 120 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 162: ...B Pin configurations 158 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 172: ...C Environmental information 168 R5906847 DP2K SLP SERIES 02 06 2017 ...