2. Getting started
2.1
Installation requirements
Environmental conditions
The table below summarizes the physical environment in which the DP2K SLP-series projector may be safely operated or stored.
Environment
Operating
Non-Operating
Ambient Temperature
10°C (50°F) to 35°C (95°F)
-15°C (5°F) to 60°C (140°F)
Air cleanliness
Clean of
fi
ce environment (equivalent with clean room
standard ISO 14644-1 ISO Class 9)
n.a.
Humidity
5% to 85% RH Non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 (-197 Ft) to 3000 m (9843 Ft)
-60 (-197 Ft) to 10000 m (32810 Ft)
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the Light Pro-
cessor Unit.
Use in high altitude conditions
When 3000 m environmental condition is combined with the highest permissible temperature (35°C ambient), the projector may be
expected to go into warning status. Hence, for high altitude conditions, we advise max 30°C ambient condition (25°C is preferred).
Furthermore, to avoid temperature warnings on laser banks, we advise in high altitude to set cooler fans to 100%.
Main Power requirements
The DP2K SLP-series projector operates from a nominal mono phase power net with a separate earth ground PE.
Projector
Power requirements
DP2K-10SLP
200-240 VAC, 50-60 Hz, 10 A at 200 VAC
DP2K-8SLP
200-240 VAC, 50-60 Hz, 10 A at 200 VAC
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not
be less than
2.5 mm
2
(12 AWG)
, minimum 300 V. Take into account that the cable gland allows a cable diameter from 8 to 13 mm.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a quali
fi
ed electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the power to the equipment
mains terminals.
W
ARNING
:
Disconnect the power to the unit mains terminals for removal of all power from the unit.
The DP2K SLP-series projector does not have a built in UPS unit.
Projector weight
Do not underestimate the weight of the DP2K SLP-series projector. The projector weight approximately 73 kg (161 lb.) without lens.
Ensure that the pedestal on which the projector is installed is capable of supporting the complete load of the system. Minimum 4
adult persons are needed to carry the projector.
Barco offers a pedestal for the DP2K SLP-series projector. This universal pedestal allows for a solid and
easy setup of the projector. The universal pedestal support 19” rack systems. (projector peripherals such as
alternative content switchers, ShowVault, etc.)
16
R5906847 DP2K SLP SERIES 02/06/2017
Summary of Contents for DP2K SLP Series
Page 1: ...DP2K SLP Series User and Installation manual R5906847 00 02 06 2017 ...
Page 4: ......
Page 15: ...1 Safety PR RESTRICTED AREA RESTRICTED AREA Image 1 2 R5906847 DP2K SLP SERIES 02 06 2017 11 ...
Page 18: ...1 Safety 14 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 44: ...5 Lenses Lens selection 40 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 86: ...7 ICMP 82 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 96: ...9 Starting up 92 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 108: ...10 Scheimpflug 104 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 116: ...11 Convergence 112 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 124: ...13 Preventative maintenance actions 120 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 162: ...B Pin configurations 158 R5906847 DP2K SLP SERIES 02 06 2017 ...
Page 172: ...C Environmental information 168 R5906847 DP2K SLP SERIES 02 06 2017 ...