4. Hardware orientation
4.2
Rear panel
About rear panel
The
fi
gure below illustrates the E2 rear panel.
Image 4-4
1
Two AC connectors
2
RJ-45 connector for 10/100 BaseT Ethernet communications
3
Two Genlock Input BNC with passive Loop-through
4
Two Expansion link cards
5
Eight Input cards (HDMI/DP, SDI, DVI)
6
Three Outputs cards (DVI, SDI)
7
One Multiviewer card (HDMI)
AC connectors
E2 is equipped with two redundant power supplies. During normal operation the load is shared equally by both supplies. If one
supply fails, the second carries the whole load. Two AC Connector are provided to connect the E2 to your facility’s AC power source
through the supplied power cords.
Input Power Speci
fi
cation: 100-240 VAC, 47-63 Hz
On each power supply there are 3 LED lights that provide status information as follows:
•
DC Output Power LED: when Green, the supply is outputting valid DC power.
•
Status LED: when amber indicates that an error has occurred.
•
AC Input Power LED: when green it indicates that the supply is connected to a valid AC power.
Therefore, during normal operating conditions, the input AC and Output DC LEDs will turn green.
Note that the power supplies are installed upside down, so the silkscreen markings will also appear upside
down.
Ethernet port
One RJ-45 connector is provided for 10/100BaseT Ethernet communications with the E2. The port is used for running the Web
Interface and for connection to an external device.
32
R5905948 E2 12/12/2014
Summary of Contents for Event Master E2
Page 1: ...E2 User s guide R5905948 00 12 12 2014...
Page 8: ...Table of contents 4 R5905948 E2 12 12 2014...
Page 16: ...2 Safety 12 R5905948 E2 12 12 2014...
Page 32: ...3 General 28 R5905948 E2 12 12 2014...
Page 82: ...6 GUI orientation Image 6 8 78 R5905948 E2 12 12 2014...
Page 94: ...6 GUI orientation Image 6 20 90 R5905948 E2 12 12 2014...
Page 115: ...6 GUI orientation Image 6 37 Thumbnail view Image 6 38 R5905948 E2 12 12 2014 111...
Page 186: ...7 System Setup 182 R5905948 E2 12 12 2014...
Page 192: ...8 Updating firmware 188 R5905948 E2 12 12 2014...
Page 196: ...9 General operation example Image 9 3 192 R5905948 E2 12 12 2014...
Page 213: ...9 General operation example Image 9 25 R5905948 E2 12 12 2014 209...
Page 216: ...9 General operation example 212 R5905948 E2 12 12 2014...
Page 220: ...10 Maintenance 10 2 Process Overview Flow chart Image 10 2 216 R5905948 E2 12 12 2014...
Page 281: ...10 Maintenance Disregard the heatsink from the spare kit R5905948 E2 12 12 2014 277...
Page 282: ...10 Maintenance 278 R5905948 E2 12 12 2014...
Page 288: ...11 Environmental information 284 R5905948 E2 12 12 2014...
Page 298: ...B Remote Control Protocol 294 R5905948 E2 12 12 2014...
Page 299: ...C Troubleshooting C TROUBLESHOOTING R5905948 E2 12 12 2014 295...
Page 300: ...C Troubleshooting 296 R5905948 E2 12 12 2014...