D. Troubleshooting
Error
code
Description
Error
Warning
Caused by
Action
7664
Blue block
temp high
Yes
Yes
High temperature on blue DMD
cooling block
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7663
Blue block
temp open
Yes
Yes
Temperature sensor on blue DMD
cooling block not connected
Call a quali
fi
ed service engineer
7662
Blue block
temp short
Yes
Yes
Temperature sensor on blue DMD
cooling block shorted
Call a quali
fi
ed service engineer
7660
Engine air temp
high
Yes
Yes
High temperature on engine
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7659
Engine air temp
open
Yes
Yes
Temperature sensor on engine not
connected
Call a quali
fi
ed service engineer
7658
Engine air temp
short
Yes
Yes
Temperature sensor on engine
shorted
Call a quali
fi
ed service engineer
7999
Fan speed
cathode too
low
Yes
Yes
fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7998
Fan speed
cathode high
-
Yes
7997
Fan speed
anode too low
Yes
Yes
fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7996
Fan speed
anode high
-
Yes
7995
Fan speed
engine too low
Yes
Yes
fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7994
Fan speed
engine high
-
Yes
7993
Fan speed cold
mirror too low
Yes
Yes
fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7992
Fan speed cold
mirror high
7991
Fan speed heat
ex. too low
Yes
Yes
fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7990
Fan speed heat
ex. high
-
Yes
7989
Fan speed
smps 1 too low
Yes
Yes
fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7987
Fan speed
smps 2 too low
Yes
Yes
fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7985
Red DMD temp
low
No
Yes
low temperature on dmd
turning on the lamp will heat up the
dmd
7984
Red DMD temp
high
Yes
Yes
high temperature on dmd
check if air slot are free; clean air
fi
lters
If problem persists, call a quali
fi
ed
service engineer
7983
Green DMD
temp low
No
Yes
low temperature on dmd
turning on the lamp will heat up the
dmd
7982
Green DMD
temp high
Yes
Yes
high temperature on dmd
check if air slot are free; clean air
fi
lters
If problem persists, call a quali
fi
ed
service engineer
7981
Blue DMD
temp low
No
Yes
low temperature on dmd
turning on the lamp will heat up the
dmd
216
R5976921 FLM R20+ PERFORMER 15/03/2010
Summary of Contents for FLM R20+ Performer
Page 1: ...FLM R20 Performer Users manual R9004430 R5976921 11 15 03 2010 ...
Page 34: ...3 Physical installation 30 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 46: ...5 Connections 42 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 62: ...7 Start up of the Adjustment Mode 58 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 72: ...8 Input menu 68 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 98: ...9 Image menu 94 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 114: ...10 Layout menu Image 10 65 Image 10 66 Image 10 67 110 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 120: ...11 Lamp menu 116 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 148: ...12 Alignment menu 144 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 168: ...13 Projector control 164 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 184: ...14 Service menu 180 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 204: ...17 Removal of the projector covers 200 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 208: ...A Dimensions 204 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 216: ...C DMX chart 212 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 224: ...D Troubleshooting 220 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 232: ...F Order info 228 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 240: ...Index 236 R5976921 FLM R20 PERFORMER 15 03 2010 ...