5. Connections
female XLR output port (N). So, the following projector in the daisy chain will still receive his RC5 code. Note that the RC5 in/out
signals are without carrier.
Mini jack plug
XLR – Remote CTRL in
XLR – Remote CTRL out
Pin Description
Pin Description
Pin Description
S
GND
1
GND
1
GND
T
RC5 in
2
RC5 in
2
RC5 out
R
n.c. or GND
3
XLR present sense
3
XLR present sense
S
R
T
A
B
C
1
2
3
2
1
3
PUSH
Image 5-12
A
Mini stereo jack plug.
•
S : SLeeve (shield)
•
R : Ring
•
T : Tip
B
Male XLR socket.
C
Female XLR socket.
RS232/422 serial communication
The communication interface of the FLM R20+ Performer supports RS232 and RS422 serial communication. You can use the
RS232/RS422 input port (O) to connect a local PC to your FLM projector. This way you can con
fi
gure and control your FLM projector
from your local PC.
Do not forget to set the projector’s baud rate (default = 115200) to match that of the computer.
The communication interface has also an active RS232/RS422 loop through output port (E). Whenever the projector has no power, a
passive loop through is created from the RS232/RS422 input port (O) to the RS232/RS422 output port (E). So, the following projector
in the daisy chain will still receive his RS232/RS422 commands.
Advantages of using RS232/RS422 serial communication:
•
easy adjustment of the projector via PC (or MAC).
•
allow storage of multiple projector con
fi
gurations and set ups.
•
wide range of control possibilities.
•
address range from 0 to 255.
•
sending data to the projector (update).
•
copying data from the projector (backup).
RS232/422 input port
RS232/422 output port
Pin Description
Pin Description
1
DCD : Data Carrier Detect
1
— (not connected) —
2
RXD- : Receive Data
2
RXD- : Receive Data
3
TXD- : Transmitted Data
3
TXD- : Transmitted Data
4
DTR : Data Terminal Ready [RS232]
TXD+ : Transmitted Data [RS422]
4
DTR : Data Terminal Ready [RS232]
TXD+ : Transmitted Data [RS422]
5
GND : Ground
5
GND : Ground
6
DSR : Data Set Ready [RS232]
RXD+ : Received Data [RS422]
6
DSR : Data Set Ready [RS232]
RXD+ : Received Data [RS422]
7
— (not connected) —
7
— (not connected) —
R5976921 FLM R20+ PERFORMER 15/03/2010
39
Summary of Contents for FLM R20+ Performer
Page 1: ...FLM R20 Performer Users manual R9004430 R5976921 11 15 03 2010 ...
Page 34: ...3 Physical installation 30 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 46: ...5 Connections 42 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 62: ...7 Start up of the Adjustment Mode 58 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 72: ...8 Input menu 68 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 98: ...9 Image menu 94 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 114: ...10 Layout menu Image 10 65 Image 10 66 Image 10 67 110 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 120: ...11 Lamp menu 116 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 148: ...12 Alignment menu 144 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 168: ...13 Projector control 164 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 184: ...14 Service menu 180 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 204: ...17 Removal of the projector covers 200 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 208: ...A Dimensions 204 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 216: ...C DMX chart 212 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 224: ...D Troubleshooting 220 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 232: ...F Order info 228 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Page 240: ...Index 236 R5976921 FLM R20 PERFORMER 15 03 2010 ...