background image

1. Introduction 

 

Barco – NGC-105 – R59770204 – Revision 00 – June 2008 

______________________________________________________________________________________________________

 1-6 

 

Do not allow anything to rest on the power cord. Do not locate this product where people will walk on the 

cord. To disconnect the cord, pull it out by the plug. Never pull the cord itself. 

 

If an extension cord is used with this product, make sure that the total of the ampere ratings on the products 

plugged into the extension cord does not exceed the extension cord ampere rating. 

 

Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage 

points or short out parts that could result in a risk of fire or electric shock.  

 

Never spill liquid of any kind on the product. Should any liquid or solid object fall into the cabinet, unplug the 

set and have it checked by qualified service personnel before resuming operations. 

 

Lightning - For extra protection for this video product during a lightning storm or when it is left unattended 

and unused for a long period of time, unplug it from the wall outlet. This will prevent damage to the unit 
due to lightning and AC power-line surges. 

 

 

 

Due to high touch current, the NGC-105 is intended to be used in a location having 
equipotential bonding: 

 

 

 

The building installation shall provide a means for connection to protective earth. 

 

The equipment is to be connected to that means. 

 

A service person shall check whether or not the socket outlet from which the equipment is to be powered 

provides a connection to the building protective earth. If not, the service person shall arrange for the installa-
tion of a protective earthing conductor from the separate protective earthing terminal to the protective earth 
wire in the building. 

1.4.3

 

Unpacking of devices 

Note advises on the packaging for unpacking! 

1.4.4

 

Installation 

 

 

 

Only authorized personnel may install the device! 

 

 

 

Use only the power cord supplied with your unit. While appearing to be similar, other power cords have not 

been safety tested at the factory and may not be used to power the unit. For a replacement power cord, 
contact your dealer. 

 

Slots and openings in the cabinet and the sides are provided for ventilation; to ensure reliable operation of 

the unit and to protect it from overheating, these openings must not be blocked or covered. The openings 
should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product 
should never be placed near or over a radiator or heat register. This unit should not be placed in a built-in in-
stallation or enclosure unless proper ventilation is provided. 

 

The maximum recommended ambient temperature for this equipment is 40° C. 

 

When using the unit in a multi-unit rack assembly or closed assembly the ambient temperature inside the 

assembly may not succeed the maximum rated ambient temperature. 

 

When installed in a rack, the installation should be such that the amount of air flow required for safe opera-

tion of the equipment is not compromised. The mounting of the equipment should be such that no hazardous 
condition is achieved due to uneven mechanical loading. 

Summary of Contents for NGC-105

Page 1: ...User s manual NGC 105...

Page 2: ...r 1 new chapter 2 new chapter 3 new chapter 4 new chapter 5 new chapter 6 new chapter 7 new chapter 8 new new The corresponding chapters are new or completely revised corr Passages of the correspondin...

Page 3: ...med immediately in writing of any complaints The period of guarantee begins on the date of transfer of risks in the case of special systems and software on the date of commissioning at the latest 30 d...

Page 4: ...____________________________________ iv Revision sheet To Barco Control Rooms GmbH An der Rossweid 5 D 76229 Karlsruhe Phone 49 721 6201 0 Fax 49 721 6201 298 E mail docu de bcd barco com Web www barc...

Page 5: ...1 5 Online manual 1 8 2 Summary 2 1 2 1 Properties 2 2 3 The device and its components 3 1 3 1 NGC 105 3 2 3 1 1 The front 3 2 3 1 2 The rear 3 3 3 2 NGS XXX 3 4 3 2 1 General interfaces and control e...

Page 6: ...________________________________________________________________________________________________________ vi 5 3 2 Cabinet 5 8 6 Technical appendix 6 1 6 1 Technical data 6 2 6 2 Order codes 6 3 7 Tro...

Page 7: ..._____________________________________________________________________________ 1 1 1 Introduction This chapter explains the structure of the manual itself and the used typographic styles and symbols Sa...

Page 8: ...mbols Safety information is provided concerning the operation of computer systems from Barco Summary gives an overview about the features of NGC 105 The device and its components describes the look of...

Page 9: ...this arrow marks a line that must be made up in two lines though meant to be one line If you do not heed instructions indicated by this symbol there is a risk of damage to the equipment If you do not...

Page 10: ...61000 3 3 and the limits for a class A digital device pursuant to Part 15 of the FCC Rules Electromagnetic immunity of NGC 105 complies with EN55024 1 4 2 Precautions For your own protection observe t...

Page 11: ...SA certified The minimum specification for the flexible cord is No 18 AWG Type SVT or SJT 3 conductor The cord set must have a rated current capacity of at least 10 A The attachment plug must be an Ea...

Page 12: ...e socket outlet from which the equipment is to be powered provides a connection to the building protective earth If not the service person shall arrange for the installa tion of a protective earthing...

Page 13: ...k not explicitly mentioned in this users manual Never open the case of NGC 105 Measurements and tests with the opened device may be carried out only in the factory or by specially trained personnel du...

Page 14: ...use Win dows Explorer to open the file index htm from the CD Follow the links to the documentation of the NGC 105 and choose the related documentation Acrobat Reader can be used to view R59770204_XX_o...

Page 15: ...Revision 00 June 2008 ______________________________________________________________________________________________________ 2 1 2 Summary This chapter gives an overview about the features of NBMS in...

Page 16: ...signals can be streamed over the Ethernet network at the appropriate quality for the viewing application without using bandwidth unnecessarily Application management The extended metadata monitoring...

Page 17: ...GC 105 provides 5 slots for NGS processing and connection boards 1 slot for optional shelf manager 1 or 2 power modules for standard or redundant power operation 2 fans all components are hot swappabl...

Page 18: ...Barco NGC 105 R59770204 Revision 00 June 2008 ______________________________________________________________________________________________________ 3 1 3 The device and its components This chapter de...

Page 19: ...ce looks like the figure below or similar PSU2 PSU1 F1 F2 F3 F4 F5 1 2 Figure 3 2 Front view of NGC 105 with open front flap 1 power switch 2 LED reserved for future use in combination with shelf mana...

Page 20: ...connection boards Figure 3 3 Rear view of NGC 105 To protect NGC 105 from overheating the air supply openings in the case shall be kept free of obstructions To disconnect the NGC 105 from the power su...

Page 21: ...al user manuals see section 1 5 Online manual 3 2 1 General interfaces and control elements The processing boards have multiple LEDs at the front panel The number of the LEDs depends on the type of th...

Page 22: ...________________________________________ 3 5 3 3 Power module The power modules have two LEDs each The LEDs are located on the upper side The power modules are located behind the front flap 1 4 4 4 3...

Page 23: ...ty for connection to a 1Gbit network for stream and data transfer This network is referred as video network Video network The video network is used to interconnect NBMS devices for data exchange Visua...

Page 24: ...acilities manager or a qualified electrician if you are not sure what type of power is supplied to the building To connect the NGC 105 to the power supply follow the steps below Make sure that the pow...

Page 25: ...______________________________ 4 1 4 Operating This chapter provides an instruction for the interactions you may do with the NGC 105 WARNING Operation actions not explained in this section bear the ri...

Page 26: ...l Switching on Switch the power switch on the front of NGC 105 to the I position to switch the device on please refer to Figure 3 1 Front view of NGC 105 The fans start spinning and the NGS boards sta...

Page 27: ...res very little maintenance Some maintenance operations are nevertheless necessary to maintain distortion free operation of NGC 105 They can be done by means of the following descriptions WARNING Main...

Page 28: ...rt on the front of the NGC 105 There is a labeling next to each slot PSU1 and PSU2 indicating the number of the slot please see the figure below PSU1 PSU2 Figure 5 1 Location and numbering of the slot...

Page 29: ...oth LEDs at the front should shine green If this is not the case you can first check whether the mains connection of this power supply is connected to a wall outlet The corresponding mains connection...

Page 30: ...the screws 5 on the top of the front please refer to Figure 3 1 Front view of NGC 105 Locate the defective power module by examining the LEDs 1 2 on the individual power modules please see above Remov...

Page 31: ...5 3 3 4 4 2 2 1 1 1 knurl screw 2 handle bar 3 LED reserved for future use in combination with shelf manager 4 number of the fan module on the housing 5 air supply openings Figure 5 3 Fan module 5 2 1...

Page 32: ...handle 2 Picture 2 below Take a new fan module out of its packaging Take care of the orientation of the fan module Fan module 1 must be rotated until knurl screw and handle are on the upper part of t...

Page 33: ...mesh It is advisable to vacuum clean the flap from both sides outside and inside to receive good results Close the front flap again Removing the front flap for cleaning The front flap can easily be de...

Page 34: ...rst switching off the device and disconnecting all power supply cords Do not use liquid cleaners or aerosol cleaners Use a soft cloth to periodically clean the cabinet Stubborn stains may be removed w...

Page 35: ...June 2008 ______________________________________________________________________________________________________ 6 1 6 Technical appendix This chapter provides tabular overviews about the technical de...

Page 36: ...nsions h w d dimensions h w d with handles 222 mm 483 mm 509 mm 8 7 in 18 9 in 20 0 in 222 mm 483 mm 551 mm 8 7 in 18 9 in 21 7 in weight with standard power supply weigth with redundant power supply...

Page 37: ...rder codes Documentation R59770204 user s manual NGC 105 English R59770205 installation and service manual NGC 105 English R59770184 NBMS hardware documentation CD ROM Hardware R9832305 NGC 105 base u...

Page 38: ...__________________________________________________ 7 1 7 Trouble shooting 7 1 Contact Helpdesk Feel free to contact us if you have any further questions Barco N V Europe President Kennedypark 35 B 850...

Page 39: ...GC 105 3 2 LEDs power modules 3 5 status 3 4 maintenance 5 1 manual 1 8 network connecting 3 6 NGC 105 front 3 2 front open 3 2 rear 3 3 technical data 6 2 NGS connecting 3 6 connection board 3 4 proc...

Reviews: