background image

BARCO PROJECTION SYSTEMS

Date :
170699

INSTALLATION MANUAL

KIT POLARISER BEAM SPLITTER FOR 6300

PROJECTORS

R812302K

Art. No. :

R5976048

Rev :

00

PBS

6300 Kit

Summary of Contents for R812302K

Page 1: ...BARCO PROJECTION SYSTEMS Date 170699 INSTALLATION MANUAL KIT POLARISER BEAM SPLITTER FOR 6300 PROJECTORS R812302K Art No R5976048 Rev 00 PBS 6300 Kit ...

Page 2: ...e Produced by BARCO NV June 1999 All rights reserved Trademarks are the rights of their respective owners BARCO n v Projection Systems Noordlaan 5 B 8520 Kuurne Belgium Tel 32 56 368211 Fax 32 56 351651 E mail sales bps barco com Visite Barco at the web http www barco com Printed in Belgium ...

Page 3: ...and let it cool down for at least 15 minutes before starting with the Analyser replacement Risk of Electrical Shock Power down the projector and unplug the power cord from the wall outlet Once the projector is cooled down and the power is off continue with the replacement procedure Antistatic Protection Steps Wear a wrist band which is connected to the ground while handling the static sensitive pa...

Page 4: ...n only be mounted in BARCOGRAPHICS 6300 projector Part Listing The kit contains one PBS R812302 R5976048 1 1 PBS Manual inst PBS 6300 Part Number Description Indication Antistatic Protection Steps Wear a wrist band which is connected to the ground while handling the static sensitive parts Illustration of the Kit ...

Page 5: ...low the next procedure 1 2 3 4 1 2 2 Open the lens cover by pivoting it backwards and hook it of Loosen the fixation screws of the motor part and pivote it upwards Open both lens locks by pulling them backwards Take the lens out of the lens house Step Action Image Illustrations on Removing the Lens Image 2 Image 1 Lens lockings Motor part To be continued on next page Necessary Parts None Fixation ...

Page 6: ...s Continued Removing the Top Cover 1 2 3 1 2 Pull the 3 rubber sealing pieces Turn out the 3 fixing screws Take off the top cover Step Action Image To remove the top cover follow the next procedure Illustrations on Top Cover Removal Image 1 Image 2 ...

Page 7: ...efore removing the PMP it must be electrically disconnected Follow the next proce dure 1 2 3 4 1 1 1 1 2 Pull out the 5 coax cables A Pull out the white power cable connector B Pull out the black connector C for the uniformity module Remove both flat cables D by pressing very carefully on both sides of the indicated points to unlock Pull out the cable Step Action Image Illustrations Image 2 Image ...

Page 8: ...essor Module Continued Removing the PMP 1 2 1 Turn out the indicated screws Take off the PMP If an SDI module is installed unplug both coax cables before taking off the PMP Step Action Image To remove the PMP follow the next procedure Illustrations Image 1 ...

Page 9: ...the projector to turn the projector upside down Necessary Tools 3 feet available in the toolkit 6300 Necessary Parts None Illustrations Image 2 Image 1 Mounting the Feet To mount the feet follow the next procedure 1 1 Turn in the feet on the indicated positions The projector is ready to be turn upside down Step Action Image ...

Page 10: ...er 7 Screwdriver 4 mm Necessary Parts None Removing the CSB module To remove the CSB module follow the next procedure 1 2 1 2 Turn out both indicated screws Pivote the module backwards Step Action Image Illustrations Image 2 Image 1 Removing Fan To remove the fan follow the next procedure 1 2 1 2 Turn out both indicated screws Slide out the fan Step Action Image Illustrations Image 2 Image 1 ...

Page 11: ...ock cover plate Necessary Tools Philips screwdriver Screwdriver Necessary Parts None To be continued on next page Illustrations Image 2 Image 1 Removing the Bottom Cover To remove the bottom cover follow the next procedure 1 2 3 4 1 2 Turn the projector upside down Turn out the 3 feet Turn out the 3 indicated fixing screws Take off the bottom cover Step Action Image ...

Page 12: ...er removing the cover turn in the feet again Turn out the indicated screw Turn the projector upside down Turn out the indicated screw on the left side and on the top side Slide off the local keypath by moving it backwards Step Action Image To move the local keypath backwards follow the next procedure Illustrations Image 1 Image 1 ...

Page 13: ...sary Tools Screwdriver Nutdriver 5 5 Nutdriver 7 Necessary Parts None Removing the Lightpath Cover To remove the lightpath cover follow the next procedure 1 2 3 1 2 Turn the projector back to normal position Turn out the indicated screws Take off the lightpath cover Step Action Image Illustrations Image 2 Image 1 ...

Page 14: ...To remove the PBS follow the next procedure 1 2 3 4 5 1 2 3 4 Turn out both fixing screws Take out the PBS Take the new PBS and remove the protection foil on both sides Insert the PBS so that the holes in the metal frame of the PBS matches the notches A B on the projector frame Secure this position by turning in both fixing screws Step Action Image Illustrations Image 2 Image 1 Image 4 Image 3 ...

Page 15: ...has to be remounted Necessary Tools Screwdriver Nutdriver 5 5 Nutdriver 7 Necessary Parts None Mounting the Lightpath Cover To mount the lightpath cover follow the next procedure 1 2 1 1 Put the lightpath cover on its place Turn in the indicated screws Step Action Image Illustrations Image 1 ...

Page 16: ...one To be continued on next page Mounting the Local Keypath 1 2 3 4 5 1 1 2 2 Slide the local keypath on its place Turn in the indicated screw on the left side and on the top side Turn the projector upside down Turn in the indicated screw Remove the feet on the bottom side of the projector Step Action Image To mount the local keypath back follow the next procedure Illustrations Image 1 Image 1 ...

Page 17: ...nued Mounting the Bottom Cover To mount the bottom cover follow the next procedure 1 2 3 4 1 2 Put the bottom cover back on its place Turn in the 3 indicated fixing screws Turn in the 3 feet Turn the projector upside down Step Action Image Illustrations Image 2 Image 1 ...

Page 18: ... None Mounting the CSB module To mount the CSB module follow the next procedure 1 2 1 2 Turn out both indicated screws Pivote the module backwards Step Action Image Mounting Fan To mount the fan follow the next procedure 1 2 1 2 Insert the fan so that it rest on the lightpath cover plate Turn in both indicated screws Step Action Image Illustrations Image 2 Image 1 Illustrations Image 2 Image 1 ...

Page 19: ...Tools Philips screwdriver Necessary Parts None To be continued on next page Mounting the PMP 1 2 3 1 1 If a SDI module on the backside of the PMP is mounted connect first the I en O coax cable to this module Put the PMP module on its place Turn in the indicated screws Step Action Image To mount the PMP follow the next procedure Illustrations Image 1 ...

Page 20: ... both sides of the indicated points to lock Connect the 5 coax cables A Connect the white power cable connector B Connect the black connector C from the uniformity module Step Action Image Illustrations Image 2 Image 1 Press to lock Press to unlock Connector connector cable Illustrations Image 2 Image 1 Removing the extra Feet To remove the extra feet follow the next procedure 1 1 2 Turn out the f...

Page 21: ...ls Screwdriver 8 mm Necessary Parts None To be continued on next page Installing the Top Cover 1 2 3 1 2 Put the top cover on the projector Turn in the 3 fixing screws Cover the fixing screws with the rubber sealing pieces Step Action Image To install the top cover follow the next procedure Illustrations on Top Cover Removal Image 1 Image 2 ...

Page 22: ...le D to the upside if a motorized lens Fix the lens by closing the both locks until they are se cured Pivote the motor part fully downwards Ensure that the teeth of the motor matches 100 those of the tooth profile only for a motorized lens If not turn the lens a little While pushing down tighten wing bolts B firmly to ensure good functioning of safety latches and motorization Re install the lens c...