9-6
Installation Mode
5976183 BARCOGRAPHICS 6500 31012001
Network configuration
What can be done ?
The necessary network addresses (configuration) can be entered so that the projector can be connected to a LAN (local area network).
Set up the network configuration
To set up the network configuration, follow the next procedure :
1
Push the cursor key
é
or
ê
to highlight 'Network configuration' (menu 1).
2
Press ENTER to display the network configuration menu (menu 2).
3
Set DHCP on or off (contact your network responsible for the correct setting in your environement).
DHCP : dynamic host configuration protocol
DHCP on : DHCP server assigned an IP address to the client (network projector).
DHCP off : the client has to fill out the IP address, the subnet mask and the default gateway.
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
menu 1
INSTALLATION
INPUT SLOTS
NO SIGNAL
LENS
TEXT BOX POSITION
QUICK ACCESS KEYS
START UP MODE
NETWORK CONFIGURATION
more ...
Select with
é
or
ê
<ENTER> to edit.
Reprogram with
é
or
ê
or numeric keys
APPLY to confirm
<EXIT> to return.
menu 2
NETWORK CONFIGURATION
DHCP : [
ON
]
IP ADDRESS : 158.150.160.200
SUBNET MASK : 158.150.160.201
DEFAULT GATEWAY : 158.150.300.300
APPLY
Entering the necessary addresses
1
Select the IP address with the cursor keys (menu 1).
2
Press ENTER to edit.
3
Enter or reprogramm the address with the numeric keys (contact your network responsible for the correct address).
An address contains 4 octets with a maximum value of 255, separated by a bullet.
4
Repeat the above steps for the subnet mask and the gateway.
5
Select APPLY and press ENTER to install the entered addresses.
If a wrong value for an octet is entered, the following error message will be displayed to indicate where the error is located. Example
of message : "Invalid octet in field Subnet mask, Maximum value is 255 for each octet ! " (menu 2).
Select with
é
or
ê
<ENTER> to edit.
Reprogram with
é
or
ê
or numeric keys
APPLY to confirm
<EXIT> to return.
menu 1
NETWORK CONFIGURATION
DHCP : [off]
IP ADDRESS :
158.150.160.200
SUBNET MASK : 158.150.160.201
DEFAULT GATEWAY : 158.150.300.300
APPLY
<ENTER> to continue
menu 2
INVALID OCTED IN
FIELD
SUBNET MAKS
MAXIMUM VALUE IS
255 FOR EACH OCTET !
800 Peripheral
What can be installed ?
- The type of output module in a RCVDS05.
- The type of communication protocol.
Defining the Output module of the RCVDS05
When a RCVDS05 is connected to the projector, the type of output module of this RCVDS05 has to be defined in the 800 peripheral
menu.
The type of output module can be :
- standard output module or
- 5 cable output module.
Summary of Contents for R9001950
Page 28: ...4 12 Connections 5976183 BARCOGRAPHICS 6500 31012001...
Page 62: ...8 22 Random Access Adjustment Mode 5976183 BARCOGRAPHICS 6500 31012001...
Page 72: ...9 10 Installation Mode 5976183 BARCOGRAPHICS 6500 31012001...
Page 102: ...D 2 Cleaning the Dustfilter 5976183 BARCOGRAPHICS 6500 31012001...