Document number: TS RHDM-1701 - K5960056
Issue: 00
Release date: 3 aug 2010
Technical specifications
Page 22 of 52
www.barco.com
8.1.2.3
Response time
•
Typical rise time: 8 ms
•
Typical fall time: 8 ms
8.1.2.4
Tolerances
8.1.2.4.1
Tolerance test colors
The display unit complies with the following tolerances for the test colors
specified in the EBU Tech 3325:
Maximal:
0045
.
0
'
'
≤
∆
v
u
Typical:
0015
.
0
'
'
≤
∆
v
u
In the table below, the Luminance Y is expressed in %. 100% is reference
white.
Test color
Description
Y (%)
u’
v’
EBU 1
Dark Skin
9.6 0
.
253 0
.5015
EBU 2
Light Skin
37.7 0
.
2366 0
.
4931
EBU 3
Light Greyish Red
29.8 0
.
2364 0
.
4848
EBU 4
Light Yellow Green
29
.
9 0
.
1807 0
.
5452
EBU 5
Light Bluish Green
29.8 0
.
1629 0
.
4552
EBU 6
Light Violet
30.1 0
.
2087 0
.
4157
EBU 7
Foliage
13
.
4 0
.
1813 0
.
5207
EBU 8
Medium Red
19.4 0
.
3248 0
.
4974
EBU 9
Medium Green
43
.
6 0
.
1505 0
.
5329
EBU 10
Medium Blue
17.2 0
.
1791 0
.
3706
EBU 11
Dark Red
6
.
5 0
.
3046 0
.
4895
EBU 12
Dark Green
19
.
9 0
.
1462 0
.
5321
EBU 13
Dark Blue
6.0 0.1825
0.3422
EBU 14
Medium Yellow Red
43.5 0
.
2726 0
.
5273
EBU 15
Medium Purple
20.0 0
.
2349 0
.
4034
The tolerances are shown for 25°C.
8.1.2.4.2
Tolerances white point and luminance
White point chromaticity and luminance is calibrated at the center of the
display for x=0.3127, y=0.3290 and Y=100 cd/m
2
(at level 1019) with the
following tolerance requirement:
%
2
0015
.
0
'
001
.
0
'
≤
∆
≤
∆
≤
∆
Y
v
u
The tolerances apply for a temperature of 25°C.
Summary of Contents for RHDM-1701