Measuring the encoder signals and adjusting the head.
Tools Required.
An oscilloscope with a minimum bandwidth off 100 MHz. Preferably a digital
memory oscilloscope e.g. TEKTRONIX 2430A.
Adjustment Procedure.
1. Take maccon board and place it on the extension board.
2. Connect T_SPH1 with A and connect T_SPH2 with B of the oscilloscope. You
can find both pins on connector JH4 on Maccon.
3. Check that both signals A and B are 90 degrees shifted. They should be within 80
and 100 degrees shifted phase.
4. Connect W_SIDX_N to the A channel.
5. Check the index puls signal.
Note: The length of the signal(5
µ
s) is drumspeed depending
T_SPH1 : A
T_SPH2 : B
Ground : JB2
Important Remark.
A logical zero = the signal is less than or equal to 0.8 volt.
A logical one = the signal is greater than or equal to 2 volt.
DO NOT forget to run ‘secor’ !!
Parameters which have to be checked after replacing the glassdisc.
6 Index to first pxl (1/32 mil) :
96 Drum circumference (1/32 mil) :
98 Y linear correction (ppm) :
41 Drum load position :
42 Drum unload position :
61 Frnt rol pos after flm rel (0=off):
62-66 Back rol pos after flm rel (0=off):
Summary of Contents for SilverWriter 800
Page 6: ...Field Service Manual December 2003 Page 6 of 276 ...
Page 8: ...Field Service Manual December 2003 Page 8 of 276 ...
Page 18: ...Field Service Manual December 2003 Page 18 of 276 ...
Page 20: ...Field Service Manual December 2003 Page 20 of 276 ...
Page 24: ...Field Service Manual December 2003 Page 24 of 276 ...
Page 95: ...Field Service Manual December 2003 Page 95 of 276 Multi FilmFeeder solid state panel ...
Page 96: ...Field Service Manual December 2003 Page 96 of 276 ...
Page 122: ...Field Service Manual December 2003 Page 122 of 276 ...
Page 130: ...Field Service Manual December 2003 Page 130 of 276 ...
Page 134: ...Field Service Manual December 2003 Page 134 of 276 ...
Page 168: ......
Page 172: ...Field Service Manual December 2003 Page 172 of 276 ...
Page 174: ...Field Service Manual December 2003 Page 174 of 276 ...
Page 187: ...Field Service Manual December 2003 Page 187 of 276 ...
Page 216: ...Field Service Manual December 2003 Page 216 of 276 ...
Page 220: ...Field Service Manual December 2003 Page 220 of 276 Main directory structure ...
Page 225: ...Field Service Manual December 2003 Page 225 of 276 Adding a DPF file in the plotter queue ...
Page 227: ...Field Service Manual December 2003 Page 227 of 276 Stop logging ...
Page 234: ...Field Service Manual December 2003 Page 234 of 276 ...
Page 240: ...Field Service Manual December 2003 Page 240 of 276 ...
Page 242: ...Field Service Manual December 2003 Page 242 of 276 ...
Page 246: ...Field Service Manual December 2003 Page 246 of 276 ...
Page 248: ...Field Service Manual December 2003 Page 248 of 276 ...
Page 252: ...Field Service Manual December 2003 Page 252 of 276 ...
Page 268: ...Field Service Manual December 2003 Page 268 of 276 ...
Page 270: ...Field Service Manual December 2003 Page 270 of 276 ...
Page 274: ...Field Service Manual December 2003 Page 274 of 276 ...