Field Service Manual
December 2003
Page 202 of 276
Focus alignment :
Remark
: Before starting the ‘scank’ command be sure that all the parameters are
correct set refering to “
Adjustment procedure Optics 600 -
Setting the default
parameters”
The covered way from B0 and B20 is not the same.
This results in a different focus point.
Look for equal and minimal spot sizes:
-> beams B0(min) = B20(min)
1. First check the actual spot size for beams B0 and B20.
LTL > -1 1 22 gpar $100001 1000 SCANK
2. Change the position of the doublet by one turn with the adjustment
screw.
3. Measure the spot size again with the "SCANK" command.
If the spot size increases, turn the adjustment screw in the opposite
direction.
4. Repeat this until you have found the right value.
5. Tighten up the screws from the doublet.
6. Execute "SCANK" for all the beams:
LTL > -1 1 22 gpar $ffffff 1000 SCANK
Remark
Spot diameter: about 7 um for a basic resolution of 4000ppi
Angle Abbe König prisma
The angle of the Abbe König prism is adapted so that the distance
between the position of B0 and B23 is -298,45 um for a basic
resolution of 4000 ppi, number of beams 24(par5), resolution
4000(par4), linear correction(par10,11,97&98 should be 0)
Align the Abbe König prism for the correct angle: the angle is
correct when the "Diff.Pos" and "Soll" values are almost the same in the
procedure "SCANK". Delta is difference between"Diff.Pos" and "Soll".
Delta should be within 3um
LTL > -1 1 22 gpar $100001 1000 SCANK
Change the Abbe König prism angle by turning into the set screws.
Remark :
Tighten the position with the center screw every time before executing
"SCANK".
Summary of Contents for SilverWriter 800
Page 6: ...Field Service Manual December 2003 Page 6 of 276 ...
Page 8: ...Field Service Manual December 2003 Page 8 of 276 ...
Page 18: ...Field Service Manual December 2003 Page 18 of 276 ...
Page 20: ...Field Service Manual December 2003 Page 20 of 276 ...
Page 24: ...Field Service Manual December 2003 Page 24 of 276 ...
Page 95: ...Field Service Manual December 2003 Page 95 of 276 Multi FilmFeeder solid state panel ...
Page 96: ...Field Service Manual December 2003 Page 96 of 276 ...
Page 122: ...Field Service Manual December 2003 Page 122 of 276 ...
Page 130: ...Field Service Manual December 2003 Page 130 of 276 ...
Page 134: ...Field Service Manual December 2003 Page 134 of 276 ...
Page 168: ......
Page 172: ...Field Service Manual December 2003 Page 172 of 276 ...
Page 174: ...Field Service Manual December 2003 Page 174 of 276 ...
Page 187: ...Field Service Manual December 2003 Page 187 of 276 ...
Page 216: ...Field Service Manual December 2003 Page 216 of 276 ...
Page 220: ...Field Service Manual December 2003 Page 220 of 276 Main directory structure ...
Page 225: ...Field Service Manual December 2003 Page 225 of 276 Adding a DPF file in the plotter queue ...
Page 227: ...Field Service Manual December 2003 Page 227 of 276 Stop logging ...
Page 234: ...Field Service Manual December 2003 Page 234 of 276 ...
Page 240: ...Field Service Manual December 2003 Page 240 of 276 ...
Page 242: ...Field Service Manual December 2003 Page 242 of 276 ...
Page 246: ...Field Service Manual December 2003 Page 246 of 276 ...
Page 248: ...Field Service Manual December 2003 Page 248 of 276 ...
Page 252: ...Field Service Manual December 2003 Page 252 of 276 ...
Page 268: ...Field Service Manual December 2003 Page 268 of 276 ...
Page 270: ...Field Service Manual December 2003 Page 270 of 276 ...
Page 274: ...Field Service Manual December 2003 Page 274 of 276 ...