Field Service Manual
December 2003
Page 253 of 276
Error list SilverWriter 800
Carriage
Error : Rule index not found
During initialisation the carriage can not find the index point of the linear scale.
►
Is something preventing the carriage of finding the index.
‼
Check for obstacles.
►
Is the carriage still moving ?
‼
Check airpressure, airpressure tubes-valves-bearings, circuit
braker(FU) installed on top of the 24V powersupply(VI)
►
When he is searching for the index, is he moving in one straight direction?
‼
If the carriage is moving from left to right, CHECK the ‘led’ on the
comut board. Perform : x y winfor ; winding 0<x<9 ; force 0 < y <
155
carriage should position to each winding. If not replace
‘COMMUT’
►
If the carriage passes the index or does not move.
‼
Clean the scale head with air pressure. Or replace Linear scale or
Maccon
►
Check Solid state(SS)(fuse) - Solid state(ET)
►
Check linear motor and cable connections.
Error :
Error too large stop on ……….. should be ………….
Carriage can not go to the position it wants to when moving at expose speed.
Overflow stop on …………….. should be ………….
Carriage can not go to the position it wants to when moving at high speed
e.g. after finding the index; when making skips while exposing
►
Is something preventing the carriage.
‼
Check for obstacles.
►
Is the errors message always around the same position ?
‼
If yes. It can be the linear scale.
►
Does the overload led on the comut board switches on during skipping or
ramping. Perform : x y winfor ; winding 0<x<9 ; force 0 < y < 155
carriage should position to each winding. If not replace ‘Comut’
‼
If ‘led’ switches on, try replacing the comut board.
►
Is the measuring head touching the scale ?
‼
Readjust the measuring head
►
Is the carriage still good moving?
‼
Check airpressure, airpressure tubes-valves-bearing tubes-bearings
►
No vibrations on carriage during exposure.
‼
Vibrations probably because too much pressure on air bearings.
►
Power supply PK400 still giving 40V ?
Summary of Contents for SilverWriter 800
Page 6: ...Field Service Manual December 2003 Page 6 of 276 ...
Page 8: ...Field Service Manual December 2003 Page 8 of 276 ...
Page 18: ...Field Service Manual December 2003 Page 18 of 276 ...
Page 20: ...Field Service Manual December 2003 Page 20 of 276 ...
Page 24: ...Field Service Manual December 2003 Page 24 of 276 ...
Page 95: ...Field Service Manual December 2003 Page 95 of 276 Multi FilmFeeder solid state panel ...
Page 96: ...Field Service Manual December 2003 Page 96 of 276 ...
Page 122: ...Field Service Manual December 2003 Page 122 of 276 ...
Page 130: ...Field Service Manual December 2003 Page 130 of 276 ...
Page 134: ...Field Service Manual December 2003 Page 134 of 276 ...
Page 168: ......
Page 172: ...Field Service Manual December 2003 Page 172 of 276 ...
Page 174: ...Field Service Manual December 2003 Page 174 of 276 ...
Page 187: ...Field Service Manual December 2003 Page 187 of 276 ...
Page 216: ...Field Service Manual December 2003 Page 216 of 276 ...
Page 220: ...Field Service Manual December 2003 Page 220 of 276 Main directory structure ...
Page 225: ...Field Service Manual December 2003 Page 225 of 276 Adding a DPF file in the plotter queue ...
Page 227: ...Field Service Manual December 2003 Page 227 of 276 Stop logging ...
Page 234: ...Field Service Manual December 2003 Page 234 of 276 ...
Page 240: ...Field Service Manual December 2003 Page 240 of 276 ...
Page 242: ...Field Service Manual December 2003 Page 242 of 276 ...
Page 246: ...Field Service Manual December 2003 Page 246 of 276 ...
Page 248: ...Field Service Manual December 2003 Page 248 of 276 ...
Page 252: ...Field Service Manual December 2003 Page 252 of 276 ...
Page 268: ...Field Service Manual December 2003 Page 268 of 276 ...
Page 270: ...Field Service Manual December 2003 Page 270 of 276 ...
Page 274: ...Field Service Manual December 2003 Page 274 of 276 ...