3
USB OUT port
The Cinema Controller is equipped with a USB port, type
“
A
”
connector, (reference
3
Image 8-5) which
can be used to power handheld devices within USB spec (MAX 500mA/5V]. No other functionality
supported (Future expansion). The USB OUT port remains operational in Standby mode.
4
3D INTERFACE
3D interface port (reference
4
Image 8-5. Can be used to connect external 3D devices to the projector. All
signals necessary for 3D projection can be provided via this connector. The 3D interface port is disabled if
the projector is in Standby mode.
5
GENERAL PURPOSE INPUT/OUTPUT (GPIO)
This 37 pin connector (reference
5
Image 8-5) can be used to send or receive trigger signals from other
devices. These input/output pins can be programmed by macros created with the Communicator
software. See user's guide of the Communicator, section Macro editor, for more information about this
functionality. Note that the General Purpose Inputs accept 24 volt maximum. The GPIO remains
operational when the projector is in Standby mode. So, if the factory predefined macro to wake up the
projector is assigned to one of the free GPI input pins the projector can be awakened via GPIO.
Enter or leave Standby mode can also be done with GPIO via two predefined Macros (not editable).
6
Wide Area Network (WAN)
Wide Area Network (WAN: 10/100/1000 base-T). Use this Ethernet port (reference
6
Image 8-5) to
connect the network which contains the DHCP server.
The Thor series can be connected to a WAN (Wide area network) (reference
6
Image 8-5). Once
connected to the WAN, users can access the projector from any location, inside or outside (if allowed)
their company network using the Communicator software. This software locates the projector on the
network if there is a DHCP server or the user can insert the correct IP-address to access the projector.
Once accessed, it is possible to check and manipulate all the projector settings. Remote diagnostics,
control and monitoring of the projector can then become a daily and very simple operation. The network
connectivity allows detection of potential errors and consequently improves service time.
7
Local Area Network (LAN: 10/100/1000 base-T)
Local Area Network (LAN: 10/100/1000 base-T) with built-in Ethernet switch (port 1 and port 2). Use for
projector control and automation. E.g. Touch Panel, content server, ... (not for content streaming!)
As there is a need to daisy chain projectors when they are on an Ethernet network, an Ethernet switch is
built in. the incoming network is hereby available for the internal PC and for the next device in the chain.
In this way a 'star' network interconnection can be avoided. The switch used is a stand alone 10/100/
1000Mbit Ethernet switch. This assures no influence on the network speed. Furthermore, this Ethernet
switch remains operational when the projector is in Standby mode.
The connectors used for these Ethernet ports are of the type RJ45, which is compatible with standard
RJ45 cable connector. Straight (most common) as well as cross linked network cables can be used. The
2 ports are functionally identical. Both ports are connected via the projector switch (Auto sensing
enabled).
Cinema Controller functions:
•
Ethernet Communication to ICMP.
•
Virtual COM port (RS232) to BARCO Controller on the USB-IN port.
•
Standardized 3D interface on board.
•
GPIO controls
•
Lensholder motors (stepper motors)
•
Stores lens files and lens type / Controls lens
•
Lens motor drivers (DC motors)
•
Controls lamp power supply
•
Stores SNMP key
•
Stores Barco IP address and host name
•
Handles reporting of errors, version info & Barco logs to Communicator
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 8: ...R5906788 03 Thor series 8...
Page 24: ...R5906788 03 Thor series 24 Safety Information...
Page 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Page 44: ...R5906788 03 Thor series 44 Installation process...
Page 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Page 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Page 110: ...R5906788 03 Thor series 110 Starting up...
Page 122: ...R5906788 03 Thor series 122 Scheimpflug...
Page 130: ...R5906788 03 Thor series 130 Convergence...
Page 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Page 160: ...R5906788 03 Thor series 160 Specifications...
Page 168: ...R5906788 03 Thor series 168 Pin configurations...
Page 172: ...R5906788 03 Thor series 172 Environmental information...
Page 176: ...Glossary R5906788 03 Thor series 176...
Page 181: ...R5906788 03 Thor series 181...
Page 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...