R5906787 /04
Thor series
47
5.6 HDD status LEDs
HDD status LEDs
5
4
Image 5-15
4
HDD I/O LED
5
RAID LED
Status LEDs on ICMP(-X)
HDD I/O
RAID
HDD Status
Off
Off
HDD idle / disk in RAID OK.
Blinking green
Off
HDD I/O activity / disk in RAID OK.
Blinking green
Slow blinking
red
HDD disks not (yet) initialized (not supported on ICMP with GEN1 storage
controller).
Blinking green
Fast blinking
red
HDD I/O activity / RAID rebuilding.
Off
Red
HDD idle / Disk error. Consult the following troubleshooting table for
curative actions.
When entering a new HDD in an ICMP(-X), the HDD RAID LED will be full red for a short time. This
is not an error, the HDD has not yet been
“
recognized
”
by the projector and ICMP(-X).
Once the HDD has been accepted by the ICMP(-X), the full red LED will start blinking in accordance
with the previous status table.
If the LED remains full red, an error has occurred. In this case, consult the following troubleshooting
table for curative actions.
Troubleshooting
Situation
Solution
One disk failed (red LED) +
RAID degraded
.
The ongoing event is not interrupted.
Note:
The disk status (RAID degraded) can be
retrieved via the (Web) Commander. See user guide
of the (Web) Commander.
1.
Switch off the power.
2.
Replace the defect HDD with approved model of
the same storage capacity. See procedure
“
Removing a HDD from the ICMP(-X)
”
, page 46,
and
“
Installing a HDD into the ICMP(-X)
, page
44. Ensure to insert the HDD firmly.
3.
Switch on the power.
Result:
As soon the new HDD is detected by the
ICMP(-X) the rebuild of the RAID is started (Blinking
red LED).
One disk failed (red LED) + Error 10580
“
local
storage not available
”
.
Note:
The disk status (Error code) can be retrieved
via the (Web) Commander. See user guide of the
(Web) Commander.
1.
Switch off the power.
2.
Replace the defect HDD with approved model of
the same storage capacity. See procedure
“
Removing a HDD from the ICMP(-X)
”
, page 46,
and
“
Installing a HDD into the ICMP(-X)
, page
44. Ensure to insert the HDD firmly.
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES User manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 28: ...R5906787 04 Thor series 28 Lenses Lens selection...
Page 74: ...R5906787 04 Thor series 74 Starting up...
Page 90: ...R5906787 04 Thor series 90 Environmental information...
Page 94: ...Glossary R5906787 04 Thor series 94...
Page 98: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906787 04 2019 10 23...