R5906787 /04
Thor series
80
Chillers (each):
Y connection: 230/400V 3W+N+PE 16A 2.5 sq mm
Delta connection: 208V / 3W+PE
Max. 16A per phase
Power consumption
Projector (Full Laser Power):
6.7 kW (2D or Polarization 3D)
3.6 kW (Barco Laser3D - 6P)
Chillers (each) (Full Laser Power):
3.0 kW (2D or Polarization 3D)
2.5 kW (Barco Laser3D - 6P)
Noise level (typical at 25°C/
77°F)
Projector (w/Chillers):
77dB(A) - Max fan speed (start up phase)
57dB(A) - Stable state
Projector (w/o Chillers):
52db(A)
Operating temperature
10 to 30 °C Max. (sea Level)
Operational humidity
75% Max. (projector and chillers)
BTU per hour
32,150 BTU/h
Airflow requirements
Air Inlet (from Rear w/Feet Down): TBC
Exhaust (from Rear w/Feet Down): TBC
Exhaust airflow
TDB
Dimensions (WxLxH)
Projector:
744 x 1,445 x 706 mm
29.3 x 56.9 x 27.8 in. (w/Feet) (excludes lens)
2 x Chillers (each):
701 x 701 x 800 mm
27.6 x 27.6 x 31.5 in.
Weight
Projector: 235 kg / ~520lbs (excludes lens)
2 x Chillers (each): ~115 kg / ~250 lbs
Shipping Dimensions
TBC (excludes lens - packaged separately)
Shipping weight
TBC (excludes lens - packaged separately)
Storage temperature
TBC
Storage humidity
TBC
Standard accessories
TBC
Certifications
CE; ETL/UL/FCC, CCC
Warranty
Limited 2 years parts and labor
Extendable up to 5 years
Safety requirements
Class 1, Risk Group 3
*
Firmware upgradable
Please contact an authorized Barco representative for details
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES User manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 28: ...R5906787 04 Thor series 28 Lenses Lens selection...
Page 74: ...R5906787 04 Thor series 74 Starting up...
Page 90: ...R5906787 04 Thor series 90 Environmental information...
Page 94: ...Glossary R5906787 04 Thor series 94...
Page 98: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906787 04 2019 10 23...