4.1 Installation requirements
Environment conditions
Table below summarizes the physical environment in which the Thor series projector may be safely operated
or stored.
Environment
Operating
Non-Operating
Ambient Temperature
10°C (50°F) to 30°C (86°F)
-15°C (5°F) to 60°C (140°F)
Air cleanliness
Clean office environment (equivalent with
cleanroom standard ISO 14644-1 ISO Class
9)
n.a.
Humidity
0% RH to 80% RH non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 m (-197 Ft) to 3000 m (9843 Ft)
Automatic decrease of brightness possible
for altitudes above 1000 m.
-60 m (-197 Ft) to 10 000 m (3
2810 Ft)
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the
Light Processor Unit.
Measures to resolve radio interference
Operation of this equipment in a residential area may cause radio interference. Possible interference shall be
solved by one of the following non limitative product installation measures:
•
Create more separation distance between projector and interfered device.
•
Change direction of the interfered device.
•
Electromagnetic shielding of the projection booth.
No interference to radio communication in neighbor buildings possible if a separation distance of 30
m (32.8 yards) is provided.
Cooling requirements
For functionality and reliability, the projector requires accurate temperature control and cooling below ambient.
Therefore a liquid cooling system is provided consisting of liquid circuits inside the projector which are
connected via hoses to external chillers. Only chiller models and hoses exclusively developed for this
application and approved by Barco are allowed to be used. Barco approved chillers models are listed on the
Barco website.
The chiller must be installed in the same environmental conditions as the projector (ambient temperature and
humidity must be the same on both projector and chiller locations). The chiller must be installed in upright
position (not tilted) conform all the installation instructions of the chiller. Maximum 3 meter height differences is
allowed between projector coupling and chiller coupling.
Sensors measure the temperature and relative humidity (RH) inside the sealed compartments of the projector.
From these measured values the dew point is calculated and compared with the temperature of the liquid
cooling in the chiller.
The dew point inside the sealed compartments of the projector must be lower than the temperature of the
cooling liquid coming from the chiller. If not, the projector will fail to startup. This to prevent drops of moisture
deposit on the electronic boards.
In case the projector fails to startup due to a dew point inside the projector that is too high, the projector and
chiller need more time to acclimatize to the environment. For a first install the time needed to acclimatize
depends on the environmental storage conditions of the projector and chiller. In extreme conditions the
acclimatization time may take several hours.
Note that the lower the relative humidity of the boot area the shorter the acclimatization time needed for the
projector and chiller.
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 8: ...R5906788 03 Thor series 8...
Page 24: ...R5906788 03 Thor series 24 Safety Information...
Page 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Page 44: ...R5906788 03 Thor series 44 Installation process...
Page 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Page 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Page 110: ...R5906788 03 Thor series 110 Starting up...
Page 122: ...R5906788 03 Thor series 122 Scheimpflug...
Page 130: ...R5906788 03 Thor series 130 Convergence...
Page 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Page 160: ...R5906788 03 Thor series 160 Specifications...
Page 168: ...R5906788 03 Thor series 168 Pin configurations...
Page 172: ...R5906788 03 Thor series 172 Environmental information...
Page 176: ...Glossary R5906788 03 Thor series 176...
Page 181: ...R5906788 03 Thor series 181...
Page 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...