11. Electronics Unit
How to install the pump inverter?
1. Install the pump inverter.
Image 11-33
Installing the pump inverter
2. Install the 2 screws (reference 1 image 11-34).
1
1
Image 11-34
Installing the 2 screws
3. Connect the 8 wires from the pump inverter. Use the Phillips screwdriver PH2 to install the screws.
5
8
7
6
1
2
3
4
Image 11-35
Connecting the wires
1
Pump motor connection ’1’ (’U’)
2
Pump motor connection ’2’ (’V’)
3
Pump motor connection ’3’ (W’)
4
’PMP INV N’
5
’PMP INV L’
6
’DC REACT’
7
’?’
80
R5906015 ULC-30A 01/02/2018
Summary of Contents for ULC-30A
Page 1: ...ULC 30A Service manual R5906015 01 01 02 2018...
Page 4: ......
Page 6: ...Table of contents Index 97 2 R5906015 ULC 30A 01 02 2018...
Page 10: ...1 Safety 6 R5906015 ULC 30A 01 02 2018...
Page 24: ...5 Covers 20 R5906015 ULC 30A 01 02 2018...
Page 28: ...6 Fan unit 24 R5906015 ULC 30A 01 02 2018...
Page 40: ...7 Coolant procedures 36 R5906015 ULC 30A 01 02 2018...
Page 70: ...10 Refrigeration unit 66 R5906015 ULC 30A 01 02 2018...
Page 92: ...11 Electronics Unit 88 R5906015 ULC 30A 01 02 2018...