7. Coolant procedures
Image 7-14
Installing the insulation cover
14.Switch off power. See procedure "Switching off power and locking the switch", page 15.
15.Install the fan. See procedure "Installation of the fan unit", page 22.
16.Install the covers. See procedure "Installing a cover", page 18.
7.4
Adding coolant to the tank
Necessary parts
Coolant liquid (30% ethylene glycol, 70% demineralized water)
This procedure assumes that power has been switched off. Unless otherwise stated, power must be off prior
to start with this procedure. To switch off power, see procedure "Switching off power and locking the switch",
page 15.
Use only Barco approved cooling liquid. Refer to the Barco website for spare parts.
How to add coolant to the tank?
1. Remove the front cover. See procedure "Removing a cover", page 17.
2. Unscrew the tank cap ring.
Image 7-15
Unscrewing the tank cap ring
3. Remove the tank cap assembly.