13. Lamp House & Lamp replacement
13.1 Introduction
Lamp and Lamp House
The ZEUS projector is delivered with a Lamp House with a xenon lamp installed. The xenon lamp is a consumable item of the
projector. Exhausted xenon lamps must be replaced on site by a quali
fi
ed service technician.
The xenon lamp is packed in a protective container or wrapped in a protective cloth. Never remove this protective container or
protective cloth without wearing adequate protective clothing (face shield, clean leather gloves, welder’s jacket).
Image 13-1
Left: Xenon lamp in protective container. Right: Xenon lamp wrapped in protective cloth.
C
AUTION
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Whenever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp, authorized protective clothing MUST
be worn!
Lamp strike policy and lamp warning/error policy versus the lamp runtime
•
The projector issues a lamp run time noti
fi
cation message (and have blue status LEDs) approximately 30 hours before the
maximum lamp runtime occurs.
•
The projector issues a lamp run time noti
fi
cation message (and have blue status LEDs) when the maximum lamp runtime
occurs.
•
The projector will always try to strike the lamp, independent of the lamp runtime.
Parts identi
fi
cation Lamp House
1
4
5
6
8
9
7
11
10
12
13
14
2
3
15
Image 13-2
1
Air inlet cathode cooling.
2
Air inlet anode cooling.
3
Positioning pin.
4
Air outlet.
5
Removable side cover.
6
Anode connection with ignitor (SPG).
7
UV blocker (with incorporated anode lamp support).
8
Cathode connection with ignitor (SPG).
9
Removable front cover (with UV blocker).
10
Handle.
11
Adjustment screw vertical lamp alignment.
12
Adjustment screw for lamp Z-alignment.
13
Lamp cathode
fi
xation screw.
14
Adjustment screw horizontal lamp alignment.
15
Lamp House
fi
xation screws.
102
R5905961 ZEUS 09/03/2015
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...