13. Lamp House & Lamp replacement
13.2 Supported xenon lamps
Cathode adaptor
A cathode adaptor is required to mount the xenon lamp in the Lamp House. The cathode adapter has to be mounted on the cathode
side of the xenon lamp prior to mounting the lamp in to the Lamp House. The purpose of the cathode adapter is to position the arc
of the xenon lamp in the middle of the re
fl
ector inside the Lamp House. Note that there is no anode adaptor for the Lamp House of
the ZEUS projector.
Image 13-4
Cathode adapter (
R858100K
)
All lamps and adapters in the table below can be used in the Lamp House of the ZEUS projector. Note that the
maximum lamp power the projector delivers depends on the type of projector and the installed lamp. Prior
to install the lamp it’s important to check with the Communicator software if the lamp is listed in the list of
supported lamps for this projector.
Supported lamp types and cathode adapter:
Lamp type & Supplier
Cathode adapter
Barco Order No.
DP2K-8S
DP2K-10S
USHIO 1.2kW DXL12BAF
R858100K
R9855961
Yes
Yes
USHIO 1.6kW DXL16BAF
R858100K
R9855972
Yes
Yes
USHIO 2.0kW DXL20BAF
R858100K
R9855955
No
Yes
USHIO 2.0kW DXL20BAF2
R858100K
R9855965
No
Yes
USHIO 2.0kW DXL20BAF/L
R858100K
R9801067
No
Yes
USHIO 2.2kW DXL22BAF
R858100K
R9855971
No
Yes
OSRAM 1.2kW DHP
R858100K
R9855959
Yes
Yes
OSRAM 2.0kW DHP
R858100K
R9855956
No
Yes
PHILIPS 2.0kW XDC2000B
R858100K
R9801071
No
Yes
The table above is subject to changes and was last updated on 29 August 2013. Consult
https://my.barco.com
for the most recent information about supported lamps for the ZEUS projector.
W
ARNING
:
Always use the correct Cathode adapter for the xenon lamp in the Lamp House. Neglecting this
may result in poor performance of the lamp and damage to the xenon lamp and Lamp House. Some adapters
looks the same, therefore check the engraved item number upon the adapter to ensure you use the right
adapter.
104
R5905961 ZEUS 09/03/2015
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...