13. Lamp House & Lamp replacement
13.5 Removal of the xenon lamp from the Lamp House
W
ARNING
:
DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE XENON LAMP.
W
ARNING
:
This procedure may only be performed by quali
fi
ed technical service personnel.
C
AUTION
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Whenever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp, authorized protective clothing MUST
be worn!
W
ARNING
:
Always wear face protection (full face shield) when handling xenon lamps.
W
ARNING
:
Always wear protective clothing (welder’s jacket) when handling xenon lamps.
W
ARNING
:
Always wear clean leather gloves with wrist protectors when handling xenon lamps.
Necessary tools
•
5mm Allen wrench.
•
Lamp protective container or protective cloth with two binders.
•
Flat blade screw driver.
•
2.5mm Allen wrench.
•
17mm open end wrench.
•
17mm nut driver.
•
Welder’s jacket (not included in the safety kit that Barco offers).
•
Full face shield with neck protection.
•
Leather gloves with wrist protection.
How to remove the xenon lamp out of the Lamp House?
1. Remove the hexagon socket head cap screw (reference 1 image 13-15) which fasten the cathode of the xenon lamp. Use a 5
mm Allen wrench. Do not release the cathode wire lug. The screw contains a spring washer and a plain washer (reference 2 &
3 image 13-15).
Note:
The cathode wire remains in its position after the screw and two washers are removed.
108
R5905961 ZEUS 09/03/2015
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...