13. Lamp House & Lamp replacement
13.9 Realignment of the lamp in its re
fl
ector
About lamp alignment
Due to ageing of the lamp, the light output will be reduced if no corrective actions are taken. To bring the light output again on
its normal level, lamp alignment should be performed on a regular time. Also when the lamp is replaced physically the alignment
procedure has to be done. Normal Z-axis alignment is enough to bring the light output again on its normal level. But sometimes,
alignment of the other axes are also necessary to reach the maximum light output. These alignments are done manually on the
Lamp House itself.
What is required?
The arc of the xenon lamp must be placed in the focal point of the Re
fl
ector for maximum light output.
Z
X
Y
Image 13-38
Each xenon lamp installation requires a realignment of the lamp in its re
fl
ector for optimal performance of the
xenon lamp. Furthermore, it is recommended to realign the lamp after the
fi
rst run time of 100 and 200 hours.
Especially the Z-axis of the lamp.
W
ARNING
:
This procedure may only be performed by quali
fi
ed technical service personnel.
Necessary tools
Communicator
How to realign the lamp in its re
fl
ector?
1. Remove the cover of the lamp compartment to gain access to the X-, Y-, and Z-axis adjustment thumbscrews of the lamp.
2. Switch on the projector and start up the lamp.
3. Via the Communicator go to the menu
Installation
>
Lamp
>
Light alignment
.
Note:
This window on the Communicator shows the measured value of the built-in light sensor of the projector. For purposes
of
fi
nding the maximum light output, a non calibrated readout serves the purpose. For correct readout levels (fL) refer to
the user guide of the Communicator to learn about system calibration.
122
R5905961 ZEUS 09/03/2015
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...