14
2.3.5.1 - Test 3.1 – Coloured Lamp Test
This test checks the operation of the coloured lamps in the machine.
To select this test, enter the self-test mode as described in 2.3.2 and step through the tests
using the RH1 button until 3.1 is indicated on the LED seven segment or alphanumeric
display.
To start the test, press the RH2 button. When the test starts each coloured lamp will be
individually switched on and off in sequence and then flash all the lamps unless a short or
open circuit bulb is found. This is indicated by the following:
•
The faulty bulb will be highlighted with a flashing lamp either side.
•
The faulty bulb will also be identified on the alpha display where fitted.
2.3.6 - Test 4 - Switch test
This test, checks the operation and positioning of the entire front panel control push buttons,
each of the IButton receptors and the door switches when operated individually.
To select this test, enter the self-test mode as described in 2.3.2 and step through the tests
using the first right hand player’s button until 4 is indicated on the LED seven segment or
alphanumeric display.
To start the test, press the RH2 button. As each of the push buttons is pressed it will light up,
the button identity will be shown on the machine display and an audible response will be
played on each movement of the button. When the RH1 button is pressed it will step on to
the next test.
Operation of the DIL switches in turn will also be indicated by an audible response. It is
important that the DIL switches are returned to their normal operating position after this test
has been carried out. (Refer to section 2.11 for button definitions).
2.3.7 - Test 5 - Display Test
This test checks the operation of the alphanumeric display, and LED’s (where used).
To select this test, enter the self-test mode as described in 2.3.2 and step through the tests
using the RH1 button until 5 is indicated on the LED seven segment or alphanumeric display.
To start the test, press the RH2 button. The alphanumeric display will then cycle through the
complete range of letters, numbers and symbols in its character set, and check all segments
of LED’s (where used). (Refer to section 2.11 for button definitions).
2.3.8 - Test 6 - Meter Test
To select this test, enter the self-test mode as described in 2.3.2 and step through the tests
using the RH1 button until 6 is indicated on the LED seven segment or alphanumeric display.
For Starpoint electronic meters, to start the serial link test, turn the refill key. An indication of
the result of the test will be given on the machines alphanumeric display i.e. PASS / FAIL.