Manual 2100-579A
Page
13 of 41
TABLE A
RESET BUTTON OPERATION
TABLE B
STATUS LIGHTS
If the burner is in the
below state:
Pushing the Reset Button Will:
Button Click
(press < 1 second)
Button Hold
(press > 1 second)
Button Hold
(press 15+ seconds)
Lockout
Reset from Soft Lockout
Reset from Restricted
(Hard) Lockout
Valve-on Delay,
Trial for Ignition,
Ignition Carryover
Go to Pump Prime
(see Below)
Disable the Burner:
Any time the burner is running,
press and hold the reset button
to disable the burner.
The burner will remain off as
long as the button is held.
Enables Pump Priming:
After the reset button has
been held for 15 seconds,
the button can then be
tapped during the next
ignition sequence to enter
Pump Prime mode.
Run (igniter is shut off)
Yellow LED flashes
to indicate cad cell
resistance. See "Cad
Cell Resistance
Indicator" for table of
resistance values.
Motor-Off Delay, Standby
No action
Pump Prime
No action
Exit Pump Prime mode and return to Standby
LED Color
On Continuously
Flashing
Red
Restricted (hard) Lockout
Soft Lockout
Green
Flame Detected (could be flame or stray light)
Recycle
Yellow
Control is in Pump Prime mode
or
Reset button currently held for 15+ seconds
Cad Cell resistance. See "Cad Cell Resistance
Indicator" section for table of resistance values.