Manual 2100-587C
Page
52 of 59
WG3S2-B, WG4S2-B, WG5S2-B 208/230/60/3
T2
NC
C
L2 L3
Au
x.
L1
T1
T3
PINK
PI
NK
5
BLUE
BLUE
5
4
3
GR
BLUE
BLUE
1 2 3
4
L3
6
8 9
7
12
10 11
BLUE
BLUE
L2
L1
BLUE
PURPLE
PURPLE
PURPLE
C
MV
NO
MV
YELLOW
ORANGE
YELLOW
YELLOW/BLACK
YELLOW
YE
LL
OW
/B
LA
CK
BR
OW
N/
W
HI
TE
YE
LL
OW
/R
ED
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
RED
RED
RED
RE
D
RE
D
RE
D/
W
HI
TE
RED/WHITE
RED
RED
RED
RED
RE
D
RE
D/
W
HI
TE
RED/WHITE
43
WHITE
RED/
RE
D
49
49
45
53
RED
31
30
29
47
RED
12
0
BLACK
BLACK
NOT USED
(OPT.)
BLACK/WHITE
16 PIN PLUG FOR
INDOOR BLOWER
MOTOR
IF OPTION
SPEED
15
0
13
5
FUSE
FOR INDOOR
BLOWER MOTOR
13
2
6
10
1
3
15
12
14
BL
AC
K/
W
HI
TE
PIN PLUG
208/230-60-3
BL
AC
K
BL
AC
K
BLACK
P3
BLACK/WHITE
BROWN
1
PL
1
2
BR
GRAY
BLACK/WHITE
BLACK
BR
OW
N
BL
AC
K/
W
HI
TE
BLACK
BLACK
BROWN
BL
AC
K/
W
HI
TE
BL
AC
K
BLACK/WHITE
BL
AC
K/
W
HT
IE
BLACK/WHTIE
SOLENOID
27
USE COPPER CONDUCTORS
SUITABLE FOR AT LEAST 75° C
WIRES CONNECT
TERM. BLOCK
GR
AY
PRESSURE
SWITCH
32
32
INDUCED
DRAFT BLOWER
SWITCH
CO
M
PR
ES
SO
R
CO
NT
AC
TO
R
51
GAS
VALVE
20
32
52
37
35
35
40
40
35
35
32
HIGH
A
32
32
32
32
34
32
32
62
28
28
28
37
28
27
27
42
44
41
38
36
47
41
33
28
28
28
FLAME
LIMIT
SPARK IGNITOR
ROLLOUT
38
PRIMARY
FLAME SENSOR
39
PRESSURE
SWITCH
32
32
28
35
38
51
51
51
46
46
46
T3
48
T1
47
T2
52
32
Optional
High Voltage
Low Voltage
15
Field
32
Factory
99
Wire Identification numbers
for Bard use only.
60
60
A
32
LOW AMBIENT
CONTROL (OPT.)
A
62
LOW
PRESSURE
4085-254 A
4
M
IN
UTE
S
LP
C
C
R
5
3
2
COMPRESSOR
HIGH SPEED
MOTOR
LP
C
CRANKCASE
16
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A
TEMPERATURE RATING OF AT LEAST 105° C EXCEPT THE IGNITION CABLE
WHICH IS 250°C HIGH VOLTAGE CABLE
OUTDOOR
FAN
INTEGRATED FURNACE CONTROL
13
11
LOW
VOLTAGE
STRIP
28
CIRCUIT BREAKER
21
MOVE RED WIRE TO
208V TAP FOR 208V
OPERATION
TRANSFORMER
18
GROUND TERMINAL
25
PH
AS
E
M
ON
IT
OR
19
INDUCED DRAFT
BLOWER RELAY
MODULE
5
4
2
1
3
240V
208V
COM
R
CONTROL
23
HEATER
C
CAPACITOR
Compressor
CC
HP
C
Y
AL
R
IF ANY ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
50
1
Model C. Breaker Capacitor
WG3S2-B
30A
10/370
WG4S2-B
40A
10/370
WG5S2-B
40A
10/370
Summary of Contents for WG3S2-A
Page 11: ...Manual 2100 587C Page 11 of 59 FIGURE 2A MOUNTING INSTRUCTIONS FOR WG3S2...
Page 12: ...Manual 2100 587C Page 12 of 59 FIGURE 2B MOUNTING INSTRUCTIONS FOR WG4S2 AND WG5S2...
Page 15: ...Manual 2100 587C Page 15 of 59 FIGURE 6 COMMON WALL MOUNTING INSTALLATIONS...
Page 25: ...Manual 2100 587C Page 25 of 59 FIGURE 11 GAS PIPE CONNECTION...