background image

1 Installation

STEP 1

Plug a standard (straight) network cable (not included)
into the network port (J1) of the Barionet and the other end 
into your hub or switch.  
You can also use a crossover network cable (not included) 
for a direct connection to your PC.

STEP 2

To power the device wire the positive terminal of your power 
supply (9..30 VDC, not included) to pin 15 (Power In +) and 
the negative terminal to pin 16 (Power In -) of connector J6.

STEP 3

Connect your power supply to an electrical outlet.

STEP 4

The LNK LED will light up green signalling established 
link.The ACT LED will blink while Barionet acquires an IP 
address,  (if no DHCP server is available this can take up to 
5 minutes).
See the next page for the ARP command procedure, or 
use the “Barix Discovery Tool” Java application (download 
the latest version from www.barix.com) on your computer 
(Windows, Mac or Linux) and click the “Get” button to find 
out which IP address the device has obtained (see picture 
at the bottom of the page). Make sure that the Ethernet 
address (MAC) matches your device (see label on the 
bottom of the device).

Now that you know the IP address proceed to the next
section “Network configuration by web browser”.

If you were not able to obtain the device’s current
IP address with the previous steps see section
"Troubleshooting".

 Network  configuration   
by web browser

Most Barix applictaions require no configuration but use 
DHCP to configure network settings dynamically.  
If you need to use static (fixed) network settings follow
steps 1 to 3, otherwise continue from step 4.

STEP 1

Open your web browser.

STEP 2

Enter the IP address of the Barionet and press Enter  
(Example: 192.168.0.12). Click on the Configuration button, 
then go to Advanced Settings/Network.

STEP 3

In order to make the application work (e.g. "Digital I/O and 
Serial Tunnel") the following parameters must be set (check 
with your network administrator):
•  static IP address (the default «0.0.0.0» sets automatic 

discovery: BootP, DHCP) and netmask

If you your devices are connected via routers also:
•  Gateway IP address
Hit the «Apply» button to save all changes. The device will 
reboot with the configured IP address.

STEP 4

To complete the application setup, download the firmware 
documentation from www.barix.com. Download the  
product manual for additional information about the hard-
ware installation, technical and mechanical details  
as well as instructions on updating or changing the loaded 
application and firmware.

Summary of Contents for BARIONET 100

Page 1: ... powering the device please read the user manual available on www barix com Firmware This device comes preloaded with standard firmware Alternative firmware can be downloaded from www barix com Support For support please contact your local dealer or visit www barix com Barix AG 3 2013 all rights reserved All information is subject to change without notice All mentioned trademarks belong to their r...

Page 2: ...mally closed 4 Relay 1 common 5 Relay 1 normally open 6 Relay 1 normally closed J4 Power bus Pin Description 1 Power 9 30 VDC out 1A max 2 Ground GND 3 Defaults for factory defaults reverting see manual J5 Dallas 1 wire bus Pin Description 1 Power 9 30 VDC out 1A max 2 Ground GND 3 1 wire data J6 I O and Power 4Watt max Pin Description 1 4 Input 1 4 Analog 0 5 VDC or Digital close to Ground 5 8 In...

Page 3: ...ing to your devices MAC address You must have administrative rights to be able to do so sudo on OSX Linux STEP 5 Now we have to make the Barionet listen to the IP address 192 168 0 6 using the Telnet command To do so type into the command window telnet 192 168 0 6 1 and hit the Enter key the number one must be there for this command to work correctly The Barionet will imme diately refuse the conne...

Page 4: ...eed to the next section Network configuration by web browser If you were not able to obtain the device s current IP address with the previous steps see section Troubleshooting 2 Network configuration by web browser Most Barix applictaions require no configuration but use DHCP to configure network settings dynamically If you need to use static fixed network settings follow steps 1 to 3 otherwise co...

Reviews: