Barix Exstreamer Gold User Manual Version 01.01
Page
16
7.9
Security settings
These settings can be used to secure the access to the
Barix Exstreamer on several levels. The status is shown
next to each password (set or not set). Access is free for
levels without a password (default setting).
Telnet / Serial configuration
Enter up to 7 characters to secure the access to the Telnet
and Serial configuration. Without a valid password the
network configuration cannot be changed.
Enter 8 characters to erase the current password.
Save configuration
Enter up to 24 characters to secure the saving of the
device configuration (Clicking on Apply). Without a valid
password the device configuration cannot be saved!
Enter 25 characters to erase the current password.
Save configuration password usage
When the password is set the user has to type in the
password in the "Save Config Password field" before hitting
the "Apply" button.
Otherwise a warning will be displayed without saving the
changes made.
View configuration
Enter up to 24 characters to secure the viewing of the
device configuration (Clicking on Config link). Without a
valid password the device configuration cannot be viewed!
Enter 25 characters to erase the current password.
View configuration password usage
When the password is set the user clicking on the "Config"
link has to type in the password in the password field of
the pop up window (the user name does not matter).
Only one user can log in at a time. Further connections will
be refused while one user is logged in.
To log out click on the "Logout" link next to the
"SECURITY" tab in the menu bar.
Please hit your browser’s Reload button if the "Logout" link
is not visible while logged in.
Control / Command
Enter up to 24 characters to secure the access to all
control and command interfaces (WEB/CGI, Serial, TCP
and UDP). Without a valid password the device cannot be
controlled. Enter 25 characters to erase the current
password.
Note
This security option should be used very carefully and is
intended for advanced users only. Since the CGI commands
used in the web interface do not make use of passwords,
setting this password would disable any control of the
Barix Exstreamer using a browser.
Level 4 to 6 (User)
Enter up to 24 characters to secure the access to
customized web pages in 3 levels. Intended for advanced
users only, for details see the Barix Exstreamer Gold
Technical Documentation). Without a valid password these
user web pages can not be viewed.
Enter 25 characters to erase the current password.
License
Type here the license you've received to enable the related
functionality.
Summary of Contents for EXSTREAMER GOLD
Page 2: ......
Page 4: ...Barix Exstreamer Gold User Manual Version 01 01 Page 2 ...
Page 26: ...Barix Exstreamer Gold User Manual Version 01 01 Page 24 ...
Page 28: ...Barix Exstreamer Gold User Manual Version 01 01 Page 26 ...
Page 30: ...Barix Exstreamer Gold User Manual Version 01 01 Page 28 ...