Barix Exstreamer Gold User Manual Version 01.01
Page
23
10.2
Network configuration using telnet
STEP 1
Unplug the power supply of the Barix Exstreamer.
STEP 2
Keep the Reset button pushed and plug in the power
supply. Release the Reset button after 5 seconds.
STEP 3
Run a command session. Type
Telnet
with the IP address
announced by SonicIP on port 9999.
Example: telnet 192.168.0.168 9999
You will see the following screen:
Hit <enter> to access the setup mode.
STEP 4
Type in <0> and hit <enter> to enter the Network
configuration. Enter all requested values.
STEP 5
Type in <9> and hit <enter> to save the Network
configuration.
10.3
Control APIs for serial and
Ethernet
For integration of the Barix Exstreamer into various
control applications and home automation systems, Barix
has developed a control API (Application Protocol
Interface) for the serial port and Ethernet UDP and TCP
control.
Serial Port control API
The serial port on the Barix Exstreamer can be used to
send control commands from a home automation system
and other PC or embedded applications. In the device
configuration the serial port can be adjusted to suit your
application.
For a detailed list of serial commands refer to the
Exstreamer Technical Documentation available on the
Barix website www.barix.com
Ethernet UDP or TCP control commands
The same control commands used on the serial port can be
used as UDP or TCP commands over Ethernet.
For more information and a detailed list of UDP and TCP
control commands refer to the Barix Exstreamer Gold
Technical Documentation available on the Barix website
www.barix.com
10.4
Automatic discovery settings
The automatic discovery functions are not executed if a
static IP address is set. To enable automatic discovery but
disable certain IP discovery functions set all but the third
value to zero. For each function you want to disable add
the value from the table below:
0.0.1.0 to disable AutoIP
0.0.2.0 to disable BOOTP
0.0.4.0 to disable DHCP
0.0.8.0 to disable IPzator
Example: 0.0.3.0 disables AutoIP and BOOTP
0.0.11.0 disables all but DHCP
Warning:
0.0.15.0 disables all discovery functions which locks you out
unless you reset the device to factory defaults by pressing
the reset button for about 5 seconds.
Summary of Contents for EXSTREAMER GOLD
Page 2: ......
Page 4: ...Barix Exstreamer Gold User Manual Version 01 01 Page 2 ...
Page 26: ...Barix Exstreamer Gold User Manual Version 01 01 Page 24 ...
Page 28: ...Barix Exstreamer Gold User Manual Version 01 01 Page 26 ...
Page 30: ...Barix Exstreamer Gold User Manual Version 01 01 Page 28 ...