SOVIS ULTRAVISION

®

 tempered glass specialized Anti-Reflective coatings on each surface of the glass.  

These coatings reduce the glare from lighting so that the products on display are more visible to your 
customers.   

While the Anti-Reflective coatings are durable, they are susceptible to scratching if abrasive materials are 
used for cleaning.  Once the glass surfaces are scratched, it is impossible to restore the original finish.  
Special care must be taken to prevent damage when cleaning the glass.  SOVIS recommends the 
following products for routine cleaning of ULTRAVISION

®

 Anti-Reflective glass: 

Cleaning Cloths

 – two products are recommended… 

Scotch-Brite

®

 High Performance Cloth

 – manufactured by 3M

®

and available in most grocery 

stores under the name 

Scotch-Brite

®

 Microfiber Cleaning Cloth

 in a 12” x 14” size.  This cloth is 

washable and may be reused as long as it remains clean. 

Spontex

®

 Microfibre Cleaning Cloth 

– distributed by Spontex

®

and available in most grocery stores 

under the same name in a 15.75” x 12” size. This cloth is washable and may be reused as long as it 
remains clean. 

Cleaning Fluid

 – for more difficult cleaning jobs, these products are recommended… 

Windex

®

- standard product only (extra-strength or specialty products may not be suitable)

Glass-Plus

®

- standard product only (extra-strength or specialty products may not be suitable)

Exceed

®

 Multi-Surface & Glass Cleaner 

– from Kay Chemical Company, Greensboro, NC

Warm Water 

Note:  equivalent store-brand glass cleaning products are normally acceptable substitutes to the brand 
name products listed above. 

The cleaning cloths named above will normally remove dust, grease, oil, and fingerprints without the need 
for cleaning fluids.  A light spray of the cleaning fluids listed above will reduce the time required for 
cleaning.  These materials have been tested and proven to clean ULTRAVISION

®

 glass without 

scratching or damaging the Anti-Reflective coatings.  If you need assistance with obtaining these 
materials, please contact your display case supplier.

Under no circumstances should the following types of materials be used for cleaning glass with 
ULTRAVISION

®

 Anti-Reflective coatings.   

 

Coarse Paper Towels 

 

Scouring Pads or Powders 

 

Steel Wool or Steel Fiber Materials 

 

Blades 

 

Acidic or highly Alkaline detergents 

 

Fluorine based detergents 

THIS DOCUMENT CONTAINS IMPORTANT INFORMATION ABOUT 

CLEANING YOUR ULTRAVISION

®

 ANTI-REFLECTIVE GLASS!  

PLEASE READ AND FOLLOW THESE INSTRUCTIONS TO 

PREVENT DAMAGE TO THE ANTI-REFLECTIVE COATINGS. 

     

C A U T I O N

Do not use these materials for cleaning glass.

 

CASE CLEANING

15

Summary of Contents for AGB

Page 1: ...ase Cleaning 14 15 Parts Ordering 16 Appendices Table of Contents To ensure proper functionality and optimum performance it is STRONGLY recommended that Hillphoenix specialty cases be installed servic...

Page 2: ...ii...

Page 3: ...ith shelf lighting systems for direct or indirect exposure to water or other liquids The use of a misting system or water hose on a display case with a shelf lighting system resulting in the direct or...

Page 4: ...installation and operations handbooks accompanied by an alert symbol paired with the word DANGER WARNING or CAUTION All warning messages will inform you of the potential hazard how to reduce the risk...

Page 5: ...parts list_09 12 energy data and parts list_01 13 endviews_03 13 text update and air ow diagram_06 13 energy data_07 13 energy data_02 14 endviews and energy data_09 14 support diagram and parts page...

Page 6: ...Watts Amps Watts Amps Watts Amps Watts AGB 4 6 8 Model Lights per Row Light Length ft Fluorescent Lighting Per Light Row Clearvoyant LED Lighting Per Light Row Standard Power Cornice or Shelf High Pow...

Page 7: ...ghted shelves Add the following for lighted shelves 4 Fluorescent 80 BTUH 3 Fluorescent 60 BTUH 4 Shelf LED 36 BTUH 4 Canopy LED 72 BTUH 3 Shelf LED 27 BTUH 3 Hi Output LED 54 BTUH 6 EPR valve is fact...

Page 8: ...cm 21 13 16 in 55 4 cm 49 13 16 in 126 5 cm 93 1 2 in 237 5 cm 93 1 2 in 237 5 cm 49 1 4 in 125 1 cm 49 1 4 in 125 1 cm REFLECTIVE REAR LOAD DOORS REFLECTIVE REAR LOAD DOORS 30 PROFILE 36 PROFILE 48...

Page 9: ...e it is delivered to the consumer Our liability ceases at the time of shipment RECEIVING CASES Examine fixtures carefully and in the event of shipping dam age and or shortages please contact the Servi...

Page 10: ...cross support and lower the horizontal support on to the shim packs Repeat on the other end of the case LOCATION This refrigerated display case has been designed for displaying and storing perishable...

Page 11: ...umper for nal t and n ish Be certain to use an appropriate cutting tool tubing or PVC cutter to ensure a smooth cut 7 Install case shelves and reconnect lights Be aware that differing shelf con gurati...

Page 12: ...ns are compliant with local codes C A U T I O N Be sure to remove all styrafoam shipping blocks from piping and refrigerant lines Failure to do so may result in case damage Fig 4 P trap drain outlet P...

Page 13: ...43 8 cm 8 case 18 in 45 7 cm 14 in 35 6 cm 28 in 71 1 cm 30 34 in 86 4 cm 36 30 in 76 2 cm 36 in 91 4 cm 26 in 66 0 cm 30 32 in 81 3 cm 36 TOEKICK 15 x 15 MECHANICAL ACCESS FOR ELECT REFRIG AND DRAIN...

Page 14: ...G E R SHOCK HAZARD Always disconnect power to case when cleaning servicing or con guring components of the light ing system Failure to do so may result in serious injury or death REPLACING T 8 LIGHTS...

Page 15: ...remove Re installing shelf luminaires 1 Place hook into shelf roll form at shelf front and rotate rear of luminaire toward the shelf 2 Depress the rear clip so that luminaire can nish rotation and un...

Page 16: ...ines see pg 8 After powering up the case be certain that all of the steps listed below have been completed to ensure proper case functionality safety and compliance with warranty terms 1 Check all lig...

Page 17: ...a case 1 Store Conditions Hillphoenix cases are designed to oper ate in an air conditioned store that maintains a 75 F 24 C store temperature and 55 max relative humidity ASHRAE conditions Case opera...

Page 18: ...he luminaires down with a soft damp cloth Avoid using harsh or abrasive cleaners as they may dam age the lights Be certain that the luminaires are complete ly dry before re energizing Clean from top t...

Page 19: ...product only extra strength or specialty products may not be suitable Glass Plus standard product only extra strength or specialty products may not be suitable Exceed Multi Surface Glass Cleaner from...

Page 20: ...case for which the part is intended Length of the part if applicable Color of part if painted or color of polymer part Whether part is for left or right hand application Quantity Data tag is located o...

Page 21: ...A1 A2 Wiring Information B1 B4 Dixell Operating Instructions C1 Sporlan Pressure Temperature Chart D1 Parts List APPENDIX 17...

Page 22: ...A1 WIRING DIAGRAM...

Page 23: ...UE LIGHT BLACK LIGHT SWITCH WHITE FROM 2 2 BLACK BALLAST WHITE BALLAST BLACK LIGHT RED LIGHT BLACK FROM BLOCK 1 1 BLACK TO DIXELL 5 41 WHITE TO DIXELL 6 42 WHITE SOL JUNCTION BOX 26 27 78 BLACK TO CHI...

Page 24: ...int 3 1 DEFROST Defrost is performed through a simple stop of the compressor Parameter IdF controls the interval between defrost cycles while its length is controlled by parameter MdF To disable the d...

Page 25: ...ow and above the humidity set point SET_RH The dehumidifying action is enabled when the humidity increases and reaches the SET_RH dbH value It is stopped when it comes back to the SET_RH The humidifyi...

Page 26: ...ring this time and then for the delay dot and doH after closing the door the temperature and humidity alarms are disabled 7 2 GENERIC ALARM I1F EAL As soon as the digital input is activated the unit w...

Page 27: ...ative humidity 20y85 no condensing Measuring and regulation range NTC probe 40 110 C 58 230 F Resolution 0 1 C or 1 C or 1 F selectable Accuracy ambient temp 25 C 0 5 C 1 digit 13 WIRING CONNECTIONS 1...

Page 28: ...29 4 381 8 17 8 3 16 4 51 5 54 3 30 4 388 0 18 7 8 17 0 52 7 55 6 31 4 394 3 19 7 2 17 7 54 0 56 9 32 4 400 7 20 6 7 18 4 55 3 58 3 33 5 407 2 21 6 1 19 1 56 6 59 6 34 6 413 8 22 5 6 19 9 58 0 61 0 3...

Page 29: ...S Wire Riser F Front Toekick G Outside Front H End Toekick I Dry or Refrigerated Lower Storage J End Panel K Fixed End Glass L Shelf Standard M Outside Back N Rear Load Doors O Light Guard P Upper Int...

Page 30: ...rned within two weeks after startup 5 If the defective part is not returned to the Manufacturer 6 To service maintenance or wear and tear parts such as lights starters and ballasts MODIFICATIONS TO GE...

Page 31: ...er directly on fan motors or any electrical connections All lighting receptacles must be dried off prior to insertion and re energizing the lighting circuit Please refer to the Use and Maintenance sec...