ENERGY DATA
Numbers are based on standard case sizes. Consult engineering.
All measurements are taken per ARI 1200 - 2002 specifications.
Engineered for stores with ambient conditions not to exceed 75
o
and 55% relative humidity.
Due to engineering improvements specifications may change without notice.
PTD-RGC COOLGENIX
Electrical Data
1
NOTE: “- - -” indicates data not applicable.
2
RRS - Refrigerated Rear Storage.
3,4 Listed BTUH indicates unlighted shelves. Add the following for lighted shelves:
4’ Fluorescent: 80 BTUH
3’ Fluorescent: 60 BTUH
4’ Shelf LED: 36 BTUH
4’ Canopy LED: 72 BTUH
3’ Shelf LED: 27 BTUH
3’ Hi-Output LED: 54 BTUH
5
Average discharge air velocity at peak of defrost.
6,7 Time-off duration for defrost with no termination control.
Model
Fans
per
Case
High Effi ciency
Fans
Anti-Condensate
Fans
Drain
Heaters
Optional Defrost
Heaters
RRS
2
Fans
per
Case
Unit Cooler Fans
120 Volts
120 Volts
120 Volts
208 Volts
120 Volts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
PTD-RGC (BASE)
6’
2
0.6
72
- - -
1
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
8’
3
0.9
108
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
10’
4
1.2
144
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
12’
4
1.2
144
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
Defrost Controls
Model
Defrosts
per Day
Run-Off
Time (min)
Electric Defrost
Timed-Off Defrost
Hot Gas Defrost
Fail-Safe
(min)
Termination
Temp (
o
F)
Fail-Safe
(min)
Termination
Temp (
o
F)
Fail-Safe
(min)
Termination
Temp (
o
F)
PTD-RGC (BASE)
DX
4
- - -
- - -
- - -
65/
6
36
42
- - -
- - -
RRS
4
- - -
- - -
- - -
65/
7
36
42
- - -
- - -
Model
Lights
per
Row
Light
Length
(ft)
Fluorescent Lighting
(Per Light Row)
Clearvoyant LED Lighting
(Per Light Row)
Standard Power
(Cornice or Shelf)
High Power
(Cornice)
120 Volts
120 Volts
120 Volts
Amps
Watts
Maximum
Allowable
Rows
Amps
Watts
Maximum
Allowable
Rows
Amps
Watts
Maximum
Allowable
Rows
PTD-RGC (BASE)
6’
2
3
0.34
40.8
- - -
0.14
16.8
- - -
0.24
28.8
- - -
8’
2
4
0.47
56.4
- - -
0.20
24.0
- - -
0.36
43.2
- - -
10’
2
5
0.61
73.2
- - -
0.24
28.8
- - -
0.44
52.8
- - -
12’
3
4
0.69
82.8
- - -
0.30
36.0
- - -
0.54
64.8
- - -
Lighting Data
Guidelines & Control Settings (DX)
Model
Conventional
3
BTUH/ft
Parallel
4
BTUH/ft
Superheat
Set Point @ Bulb
(
o
F)
Evaporator
(
o
F)
Discharge
Air
(
o
F)
Discharge Air
5
Velocity
(FPM)
PTD-RGC (BASE)
DX
485
445
6-8
26
29
250
RRS
109
100
10
26
29
200
2
Summary of Contents for GMD-R
Page 2: ...ii...