ENERGY DATA
PTD-RGC COOLGENIX
Numbers are based on standard case sizes. Consult engineering.
All measurements are taken per ARI 1200 - 2002 specifications.
Engineered for stores with ambient conditions not to exceed 75
o
and 55% relative humidity.
Due to engineering improvements specifications may change without notice.
Electrical Data
1
NOTE: “- - -” indicates data not applicable.
2
Semi Self-Contained is NOT available in a 4’ case.
*
Listed data is based on the factory recommended default fresh meat temperature settings.
*
Shelves are not recommended for fresh meat applications.
Model
Defrosts
per Day
Run-Off
Time (min)
Electric Defrost
Timed-Off Defrost
Hot Gas Defrost
Fail-Safe
(min)
Termination
Temp (
o
F)
Fail-Safe
(min)
Termination
Temp (
o
F)
Fail-Safe
(min)
Termination
Temp (
o
F)
PTD-RGC (DOME)
1
5
- - -
- - -
60
45
- - -
- - -
Guidelines & Control Settings (Remote Secondary/Semi-Self Contained
2
)
Defrost Controls
Model
Fans
per
Case
High Effi ciency
Fans
Anti-Condensate
Fans
Drain
Heaters
Optional Defrost
Heaters
120 Volts
120 Volts
120 Volts
208 Volts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
PTD-RGC (DOME)
4’
- - -
1
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
6’
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
8’
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
10’
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
12’
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
Model
Lights
per
Row
Light
Length
(ft)
Fluorescent
Lighting
(Per Light Row)
Clearvoyant LED Lighting
(Per Light Row)
Standard Power
(Cornice or Shelf)
High Power
(Cornice)
120 Volts
120 Volts
120 Volts
Amps
Watts
Maximum
Allowable
Rows
Amps
Watts
Maximum
Allowable
Rows
Amps
Watts
Maximum
Allowable
Rows
PTD-RGC (DOME)
4’
- - -
- - -
- - -
6’
2
3
0.37
44.0
- - -
0.14
16.6
- - -
0.24
29.8
- - -
8’
2
4
0.47
56.0
- - -
0.20
23.8
- - -
0.36
43.0
- - -
10’
3
3
0.71
85.0
- - -
0.21
25.2
- - -
0.40
48.0
- - -
12’
3
4
0.71
85.0
- - -
0.30
35.7
- - -
0.54
64.5
- - -
Lighting Data
Cut-In/Cut-Out
Model
Cut-In
Temp (
o
F)
Cut-Out
Temp (
o
F)
PTD-RGC (DOME)
Pans
33
29
Top Coil
36
31
Model
Conventional
BTUH/ft
Parallel
BTUH/ft
Glycol
Supply Temp.
(
o
F)
DX SST
Chiller
Temp. (
o
F)
Glycol
Flow Rate
GPM/ft
Glycol
Charge
GAL/ft
Glycol
Max. Working
Pressure (PSIG)
Max. Static
Pressure
(PSIG)
PTD-RGC (DOME)
250
240
26
20
0.25
0.20
50
- - -
3
Summary of Contents for GMD-R
Page 2: ...ii...