Operation and Maintenance Manual
Last Updated - 08/31/2016
495B ML TM (S)
52
COLLECTOR TROUBLE SHOOTING CONTINUED...
11. Place the clean housing on a clean, firm work surface with the chamfer facing up.
12. Lightly oil the bore of the housing and the seals that are installed on the spool.
13. Install both wear rings.
14. Carefully place the spool into the chamfer. Gently (by hand) apply downward pressure on the spool until at least
the second seal is inserted into the bore. Using a plastic mallet, gently and slowly tap the spool into the housing
until it appears to be almost all the way home.
15. Then flip the entire collector over and tap on the housing (not the mounting ears) and the spool will extend out of
the housing approximately 1/8 of an inch.
NOTE: If a hydraulic press is available, it can be used in place of the plastic mallet.
16. Place the thrust washer around the spool, install the retaining plate and Loctite the cap screws in place.
17. Torque cap screws to 45 Ft. Lbs.
Summary of Contents for 495B SD
Page 3: ...Introduction...
Page 7: ......
Page 16: ...Maintenance...
Page 19: ...Operation and Maintenance Manual 495B ML TM S 19 Last Updated 08 31 2016 SERVICE SCHEDULE...
Page 29: ...Hydraulic...
Page 57: ...Electrical...
Page 58: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 58 ELECTRICAL SCHEMATIC...
Page 78: ...Maintenance...
Page 88: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 88 Structural...
Page 95: ...Trouble Shooting...