1. Take measurements at 8 equally spaced locations on the bearing. See Figure 2.
2. Rotate machines upper works so that the centerline of the boom is aligned with the first measuring location and
the centerline of the counterweight is aligned with another measuring location.
3. Place one dial indicator under the centerline of the boom so that a measurement will be taken from the upper
bearing mounting surface or the upper bearing ring to the lower bearing mounting surface or the lower bearing
ring (mark the locations of the dial indicator base and the dial indicator contact point so that the readings can be
repeated). See Figure 1. Set dial indicator.
4. Balance the machine so as to have zero moment load on the bearing. This is done by adjusting the boom angle.
Zero moment is when the upper race is at its lowest position at both front and rear of the upper works - mark
boom angle position so that it may be returned to the same neutral position.
5. Lower the boom to a horizontal position. Do not load the attachment or add extra weight.
6. Read dial indicators and record the measurements.
7. Elevate the boom back to the neutral position (dial indicator should return to zero).
8. Rotate the upper works to the next measurement location and take readings the same as above.
Figure 1
Possible Indicator Position
Dial Indicator
Upper Bearing
Bearing Mounting Bolts
Lower Bearing Mounting
Surface (machine)
Upper Bearing
Mounting Surface
(machine)
TURNTABLE BEARING MAINTENANCE CONTINUED...
Figure 2
Measurement Locations
Lower Bearing
Summary of Contents for 495B SD
Page 3: ...Introduction...
Page 7: ......
Page 16: ...Maintenance...
Page 19: ...Operation and Maintenance Manual 495B ML TM S 19 Last Updated 08 31 2016 SERVICE SCHEDULE...
Page 29: ...Hydraulic...
Page 57: ...Electrical...
Page 58: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 58 ELECTRICAL SCHEMATIC...
Page 78: ...Maintenance...
Page 88: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 88 Structural...
Page 95: ...Trouble Shooting...