page 69
595 ML CRL (S)
800-00177
TWO, THREE AND FOUR PAD PUMP DRIVES
2 PAD PUMP DRIVE
3 PAD PUMP DRIVE
4 PAD PUMP DRIVE
Figure 1
LUBRICANT RECOMMENDATIONS AND FLUID CHANGING PROCEDURES
Lubricant Type:
EP 80-90 gear fluid (except for direct drive models).
Lubricant Grade:
Weather Temperature
Below -10 degrees F (-23 degrees C)
=
Use 75 W.
Above -10 degrees F and up to 100 degrees F (37.8 degrees C) = Use 80 W/90.
Above 100 degrees F (37.8 degrees C) =
Use 85 W/140.
It is recommended that the fluid level be checked daily, at the same time checking for fluid leaks.
Because the lubricant system is the heart of the unit, it is especially important that the fluid be kept clean.
The following procedures should be followed:
1.
Stop engine before checking or adding fluid.
2.
Check unit for operational warning tags. Heed all warnings.
3.
Clean around fluid fill before checking or adding fluid.
4.
Change the fluid after every 400 hours of operation. Also, the fluid in the unit should be changed
whenever the fluid level shows traces of dirt or effects of high temperature, evidenced by
discoloration or strong odor.
5.
Drain the fluid while the unit is still warm, examining for contamination or metal particles.
(FOR FUNK PUMP DRIVES)
PUMP DRIVE MAINTENANCE
Summary of Contents for 595ML
Page 3: ...page3 595 ML CRL S 800 00177 Introduction Marker...
Page 16: ...page16 595 ML CRL S 800 00177 Maintenance A PREVENTIVE MAINTENANCE Maintenance...
Page 27: ...page27 595 ML CRL S 800 00177 Maintenance B HYDRAULIC SYSTEM...
Page 33: ...page33 595 ML CRL S 800 00177 HYDRAULIC PRESSURE ADJUSTMENT CONTINUED 558 01699...
Page 44: ...page44 595 ML CRL S 800 00177 Maintenance C ELECTRICAL SYSTEM MAINTENANCE...
Page 67: ...page67 595 ML CRL S 800 00177 Maintenance D POWER UNIT MAINTENANCE...
Page 77: ...page77 595 ML CRL S 800 00177 Structural E STRUCTURAL MAINTENANCE...
Page 84: ...page84 595 ML CRL S 800 00177 Trouble Shooting Marker Marker Marker...