Machine will not turn in either
direction.
Damaged lines.
Pump pressure inproperly
adjusted.
Track drive motor needs service.
Damaged lines.
Pump pressure improperly
adjusted.
Track drive motor needs service.
Replace lines.
Adjust per specifications.
Repair or replace track drive
motor.
Replace lines.
Adjust per specifications.
Repair or replace track drive
motor.
Slow response to track travel foot
pedals.
Machine will not turn on one
direction.
Damaged or broken foot pedal
valve.
Relief valve needs service.
Repair or replace foot pedal valve.
Repair or replace valve.