475 A CRL
800-00167
S10A SWING MOTOR GEARBOX MAINTENANCE CONTINUED...
10. Roll test the unit in both clockwise and counterclockwise directions. Perform the same number of turns in
each direction as the ratio of the unit. The ratio is the same as the last two digits in the model number
found on the ID tag of the unit. For example, if the model number is S10AC4470, then it should be rolled
70 times in both directions.
11. Leak test the unit at a pressure of 8 P.S.I. for 2-3 minutes.
12. At this point, the main assembly is complete.
FILLING WITH OIL AND OIL
FILLING WITH OIL AND OIL
FILLING WITH OIL AND OIL
FILLING WITH OIL AND OIL
FILLING WITH OIL AND OIL
CHANGE INTERVALS
CHANGE INTERVALS
CHANGE INTERVALS
CHANGE INTERVALS
CHANGE INTERVALS
For normal applications, use EP90 gear fluid.
Fill until oil is as high as top of cluster bearings - see
illustration at right.
Check oil level daily.
Initial oil change should be done after 50 hours of
operating time. Change every 400 hours after that.
Minimum