13-7
®
INSPECTION & SERVICE SCHEDULE
The following maintenance schedule must be followed to ensure safe operation and long service
life of your BARKO machine or attachment
. The listed maintenance intervals are for normal use
applications. Maintenance intervals may need to be shortened to account for extreme operating conditions.
To avoid serious personal injury or property damage, ensure that all safety
information, warnings and instructions are read and understood before
performing any of these maintenance procedures.
Refer to chapters in the Barko Service Manual or in component manufacturer
manuals supplied with your BARKO machine or attachment for specific
maintenance procedures.
WARNING
!
NOTICE
remove flammable debris
X
check for wear and for loose
or missing fasteners
X
inspect entire machine for
stress, wear, cracks,
damage, etc.
X
grease all fittings
X
use recommended grease per
application
check torque of nuts & bolts
X
retorque if necessary
steam clean entire machine
X
or more frequently if
necessary
inspect hoses, tubes, fittings
and filters for leaks
X
inspect cylinders for leaks
and damage
X
Air Tank and Reservoir-
drain
X
if equipped - note there are
two tanks each with a
separate drain
Air Compressor Discharge
Lines-
clean
X
if equipped
Air Conditioner-
run
X
run for minimum of 5 minutes
every 30 days to circulate the
refrigerant system
Manifold Gauge Check-
check a/c refrigerant
X
performed only by qualified
HVAC service personnel
Bushings, Pins and Shims-
inspect for wear and play,
lubricate
X
***see Chapter 28 for schematics and information on auto-lube system if equipped***
***see Chapter 22 for schematics***
20 Hydraulic
21
Fuel
13 General /
Structural
***see Chapters 60 Power Package and 70 Reservoirs for fuel system components***
22 Electrical
24 Pneumatic
26
HVAC
28
Grease
30
Boom
Daily
50 Hours
100 Hours
500 Hours
1000 Hours
2000 Hours
4500 Hours
5000 Hours
Yearly
2
Years
3
Years
4
Years
INTERVAL
NOTES /
INSTRUCTIONS
CHAPTER REF
LOCATION
/ SYSTEM
INSPECTION &
SERVICE REQUIRED
07/26/2018
Updated
OPERATOR’S
Summary of Contents for 295B
Page 4: ...THIS PAGE INTENTIONALLY BLANK SUPERIOR WI USA www barko com...
Page 6: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 27: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 60: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 64: ...THIS PAGE LEFT INTENTIONALLY BLANK...