AIR CLEANERS WITH VACUATOR VALVE
On vacuator valve equipped models, (see figure 3) dust
cup service is cut to a minimum. A quick check to see
that the vacuator valve is not inverted, damaged, or
plugged is all that is necessary.
DUST CUP
VACUATOR VALVE
Figure 3
CHECKING AIR CLEANER RESTRICTION
Check the Air Cleaner Restriction Indicator daily for restriction. Restriction is caused by dust and dirt
accumulating on the Air Cleaner Element. The method used to check the restriction will depend upon the type of Air
Cleaner on the machine.
AIR CLEANERS WITH RESTRICTION INDICATORS
These air cleaners have a restriction indicator mounted to the Air
Cleaner body (see Figure 4). The indicator plunger will be in the
green zone when the Air Cleaner is empty - and will move up towards
the red
zone when the Air Cleaner is full of dust and dirt. When
in the red zone, this means the Air Cleaner
element needs to be
replaced. See Replacing The Air Cleaner Element later on.
Figure 4
AIR CLEANERS WITHOUT RESTRICTION INDICATORS:
Measure the restriction of the Air Cleaner with a service gauge, or a water manometer at the restriction tap provided
in the Air Cleaner, the transfer pipe, or the blower intake. Replace the element only when the restriction has reached
the maximum allowed by the engine manufacturer. Contact the Barko Service Department for maximum values and
any other questions concerning this method.
Check the Air Cleaner Assembly daily for cracks,
loose clamps, or any other damage. If debris is able
to bypass the Air Cleaner for any reason, it can
damage
the
engine.
REPLACING THE AIR CLEANER ELEMENT
For minimum vehicle downtime, replace dirty air cleaner element with a new element. DO NOT TRY TO CLEAN THE
ELEMENT! Do not leave air cleaner open to the environment longer than it takes to remove element, inspect and
clean inside of air cleaner body, and install a new element.
When restriction indicates that element servicing is required, see the replacement steps on the next page.
SAFETY ELEMENT SERVICE (IF APPLICABLE)
The safety element is not intended to be cleaned.
For maximum engine protection and air cleaner service life, replace the safety element with a new safety element
every third primary element change.
RESTRICTION
INDICATOR
AIR CLEANER MAINTENANCE CONTINUED...
Summary of Contents for 495B - SE
Page 3: ...Introduction...
Page 15: ...Maintenance...
Page 18: ...Service Manual Last Updated 9 28 2016 495B SE S 18 SERVICE SCHEDULE...
Page 19: ...Service Manual 495B SE S 19 Last Updated 9 28 2016 SERVICE SCHEDULE CONTINUED...
Page 20: ...Service Manual Last Updated 9 28 2016 495B SE S 20 SERVICE SCHEDULE CONTINUED...
Page 21: ...Service Manual 495B SE S 21 Last Updated 9 28 2016 SERVICE SCHEDULE CONTINUED...
Page 22: ...Service Manual Last Updated 9 28 2016 495B SE S 22 SERVICE SCHEDULE CONTINUED...
Page 28: ...Hydraulic...
Page 29: ...Service Manual 495B SE S 29 Last Updated 9 28 2016 HYDRAULIC DRAWING 603 01594...
Page 30: ...Service Manual Last Updated 9 28 2016 495B SE S 30 HYDRAULIC SERVO DRAWING 603 01593...
Page 31: ...Service Manual 495B SE S 31 Last Updated 9 28 2016 HYDRAULIC SCHEMATIC 607 00185...
Page 32: ...Service Manual Last Updated 9 28 2016 495B SE S 32 HYDRAULIC DRAWING TANDEM 603 01574...
Page 33: ...Service Manual 495B SE S 33 Last Updated 9 28 2016 HYDRAULIC SERVO TANDEM 603 01573...
Page 34: ...Service Manual Last Updated 9 28 2016 495B SE S 34 HYDRAULIC SCHEMATIC TANDEM 607 00184...
Page 56: ...Electrical...
Page 71: ...Service Manual 495B SE S 71 Last Updated 9 28 2016 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 72: ...Service Manual Last Updated 9 28 2016 495B SE S 72 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 73: ...Service Manual 495B SE S 73 Last Updated 9 28 2016 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 74: ...Service Manual Last Updated 9 28 2016 495B SE S 74 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 78: ...Maintenance...
Page 88: ...Structural...
Page 93: ...Trouble Shooting...