background image

Before installation, read the following 

instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 

bodily  injury,  death  and/or  property 

damage.  Each  Barmesa  product  is 

carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 

operating  problems,  assuring  years 
of trouble-free service. 

01

General Safety Information

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation,  wiring,  and 

junc tion  connec tions  must  be  in 
accordance  with  the  National  Electric 
Code  and  all  applicable  state  and  local 
codes. Requirements may vary depending 
on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 

qualified personnel only.

WARNING

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  104º  F. 

Do  not

 

exceed manufacturers recommended 
maximum performance, as this could 
cause the motor to overheat.

WARNING

Ground  Fault  Circuit 

Interrupter  (GFCI)  to  be  used  with 

plug-in type power cord.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 

CLEANED,  SANITIZED,  OR

DECONTAMINATED  PRIOR  TO 
SHIPMENT, TO INSURE EMPLOYEES 
WILL NOT BE EXPOSED TO HEALTH 

HAZARDS  IN  HANDLING  SAID 
MATERIAL. ALL APPLICABLE LAWS 
AND REGULATIONS SHALL APPLY.

Keep  clear  of  suction  and 

discharge  openings.  Do  not 

insert  fingers  in  pump  with

power connected; the rotating cutter 

and/or  impeller  can  cause  serious 

injury.

Always  wear  eye  protection 

when working on pumps. Do 
not wear loose clothing that

may  become  entangled  in  moving 

parts.

Pumps  build  up  heat 
and  pressure  during 

operation.  Allow  time 

fo r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
pump  or  any  accessor y  items 

associated with or near the pump.

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 

swimming  pools  or  water 
installations  where  there  is

DANGER

human contact with pumped fluid.

Risk of electric shock. To 

reduce risk of electric shock, 

always  disconnect  pump 
from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

Do  not

  lift,  carry  or 

hang pump by the electrical 

c a b l e s.   D a m a g e   to   t h e 

electrical  cables  can  cause

DANGER

shock, burns or death. 

Never

 handle 

connected  power  cords  with  wet 

hands. Use appropriate lifting device.

S u m p   a n d   s e w a g e 

pumps often handle materials which 

could  cause  illness  or  disease.  Wear 
adequate  protective  clothing  when 

working  on  a  used  pump  or  piping. 
Never enter a basin after it has been 

used.

WARNING

Failure  to  permanently 

ground the pump, motor and 

controls  before  connecting 

to  power  can  cause  shock,

DANGER

burns or death.

These pumps are not to 

be  installed  in  locations 
classified  as  hazardous  in 

accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

The  Uniform  Plumbing 

Code  (UPC)  states  that  sewage 
systems shall have an audio and visual 
alarm that signals a malfunction of the 

systems,  that  are  required  to  reduce 

the potencial for property damage.

WARNING

1 Phase Models

Amps:

Volts:

3 Phase Models

Amps L1-2:

Volts L1-2:

Amps L2-3:

Volts L2-3:

Amps L3-1:

Volts L3-1:

Model Number: _____________________

Serial: ____________

PHASE: ______ HP: __________________

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 

Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 

Also  record  the  Voltage  and  Current 
Readings at Startup:

WARNING

 "Danger" indicates an 

imminently  hazardous  situation 

which, if not avoided, WILL result in 
death or serious injury.

"Warning"  indicates 

an  imminenty  hazardous  situation 
which, if not avoided, MAY result in 
death or serious injury.

"Caution"  indicates  a 

potentially  hazardous  situation 
which, if not avoided, MAY result in 

minor or moderate injury.

DANGER

CAUTION

barmesapumps.com

Summary of Contents for 4BSE-DS Series

Page 1: ...lation Operation Maintenance Manual Submersible Solids Handling Pumps 4BSE DS 4 5 7 5 11 3 15 HP 1750 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapum...

Page 2: ...ry items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric sh...

Page 3: ...oad protection to be included in controlpanel ClassFinsulation Normallyopen N O included requiresrelayincontrolpanel TEMPERATURESENSOR Normallyclosed N C included requiresrelayincontrolpanel OPTIONALE...

Page 4: ...lex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installed or removed without requiring personnel to enter the station or resting on the basin floor Discharge...

Page 5: ...phase information stamped on the pump name plate 2 Check Pump Rotation Improper motor rotation can result in poor pump performance and can damage the motor and or pump Check rotation on three phase un...

Page 6: ...duit box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to 15 ft lbs Oil Replacement Seal Chamber Refill chamber completely full with new cooling oi...

Page 7: ...wave washer Remove upper bearing 2 with a wheel puller if Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the temperature sensors by checking for continuity...

Page 8: ...4 if required See Figure 4 Bring motor wires through opening in top of motor housing 3 check sleeving and replace if damaged Position square ring 5 in conduit box 4 and reconnect leads using connector...

Page 9: ...GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead Number Green Green Black 1 and 7 Red 2 and 8 White 3 and 9 4 5 and 6 together Figure 5 T2 T3 T4 T7 T5 T8 T6 T9 G L2 L3 RED WHITE...

Page 10: ...Figure 6 09 Repair Parts barmesapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List...

Page 11: ...t For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List 40 40 4 5 H P SINGLE PHASE 230 7 5 H P SINGLE PHASE 230 barme...

Page 12: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Page 13: ......

Page 14: ......

Reviews: