background image

1

Before installation, read the following 
instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 
bodily  injury,  death  and/or  property 
damage.  Each  Barmesa  product  is 
carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 
operating  problems,  assuring  years 
of trouble-free service. 

General Safety Information

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 
qualified personnel only.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 
CLEANED,  SANITIZED,  OR

D E CO N TA M I N AT E D   P R I O R   TO 
S H I P M E N T ,   T O   I N S U R E 
E M P L O Y E E S   W I L L   N O T   B E 
EXPOSED TO HEALTH HAZARDS IN 
HANDLING  SAID  MATERIAL.  ALL 
A P P L I C A B L E   L A W S   A N D 
R E G U L AT I O N S   S H A L L   A P P LY .

Keep  clear  of  suction  and 
discharge  openings.  Do  not 
insert  fingers  in  pump  with

power connected; the rotating cutter 
and/or  impeller  can  cause  serious 
injury.

Always  wear  eye  protection 
when working on pumps. Do 
not wear loose clothing that

may  become  entangled  in  moving 
parts.

Pumps  build  up  heat 
and  pressure  during 
operation.  Allow  time 
f o r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
p u m p   o r   a n y   a c c e s s o r y   i t e m s 
associated with or near the pump.

WARNING

 "Danger" indicates an 

imminently  hazardous  situation 
which, if not avoided, WILL result in 
death or serious injury.

"Warning"  indicates 

an  imminenty  hazardous  situation 
which, if not avoided, MAY result in 
death or serious injury.

"Caution"  indicates  a 

potentially  hazardous  situation 
which, if not avoided, MAY result in 
minor or moderate injury.

DANGER

CAUTION

Operation  against  a 
closed  discharge  valve 
will  cause  premature 
bearing and seal failure

WARNING

on any pump, and on end suction and 
self priming pump the heat build may 
cause  the  generation  of  steam  with 
resulting  dangerous  pressures.  It  is 
recommended  that  a  high  case 
temperature switch or pressure relief 
valve be installed on the pump body.

M a k e   s u r e   l i f t i n g 

handles  are  securely  fastened  each 
time  before  lifting. 

Do  not

  operate 

pump without safety devices in place. 
Always  replace  safety  devices  that 
have been removed during service or 
repair.  S ecure  the  pump  in  its 
operating  position  so  it  can  not  tip 
over, fall or slide.

CAUTION

Installation, wiring, and 

junction  connections  must  be  in 
accordance with the National Electric 
Code and all applicable state and local 
codes.  Requirements  may  var y 
depending on usage and location.

WARNING

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 
swimming  pools  or  water 
installations  where  there  is

DANGER

human contact with pumped fluid.

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  160º  F. 

Do  not

 

exceed manufacturers recommended 
maximum performance, as this could 
cause the motor to overheat.

WARNING

Risk of electric shock. To 

reduce risk of electric shock, 
always  disconnect  pump 
from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

C a r e f u l l y   r e a d 

instruction  manuals  supplied  with 
motor  or  engine  before  operating or 
servicing.

WARNING

These pumps are not to 

be  installed  in  locations 
classified  as  hazardous  in 
accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 
Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 
Also  record  the  Voltage  and  Current 
Readings at Startup:

Model Number: ____________________

Serial: ____________________

Amps:_______  Voltage:_______

Phase:_______  HP:_______

barmesa.com

Summary of Contents for BSP5CU

Page 1: ...ation Maintenance Manual Self Priming Frame Mounted Pump BSP5CU BSP7CU 1 x 1 2 x 2 Universal Drive IMPORTANT Read all instructions in this manual before operating or servicing a pump Last update 10 18...

Page 2: ...norormoderateinjury DANGER CAUTION Operation against a closed discharge valve will cause premature bearing and seal failure WARNING on any pump and on end suction and self priming pump the heat build...

Page 3: ...Stainlesssteel O RINGS Buna N PAINT Airdryenamel waterbased SEAL Mechanical self lubricating Ceramic stationary part carbon ring seal and exclusionintherotatingpart Buna Nelastomerandstainlesssteelspr...

Page 4: ...horizontal suction lines should slope up to the pump to avoid trapped air pockets All piping should be properly supported 4Priming Remove pipe plug in top of body and fill the pump body completely wi...

Page 5: ...eplace complete seal 4Shaft seal To reassemble lightly oil ring and press stationary member over shaft and into pedestal Lightly oil shaft and inner surface of bellows of rotating member With lapped s...

Page 6: ...5 Service Repair For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com...

Page 7: ...6 Repair Parts For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com...

Page 8: ...essive noise 1 Fill pump body with water 2 Shorten suction head 3 Lower suction head install foot valve and prime 4 Disassemble pump and clean out impeller 5 Repair or replace suction line 6 Match foo...

Page 9: ...8 barmesa com...

Reviews: