C-4) Electrical Connections:
C-4.1) Power & Sensor Cords:

The cord assembly mounted to the pump must not be modifi ed 
in any way except for shortening to a specifi c application. 
Any splice between the pump and the control panel must be 
made in accordance with all applicable electric codes. It is 
recommended that a junction box, if used, be mounted outside 
the sump or be of at least NEMA 4 (EEMAC-4) construction if 
located within the wet well. 

DO NOT USE THE POWER OR 

SENSOR CORDS TO LIFT PUMP.

 

NOTE: The White Wire Is Not A Neutral Or Ground Lead. 
The Black, White And Red Leads Are Power Carrying
Conductors. The Green Lead Is For Connection To 
Ground.

 

C-4.2) Overload Protection :
C-4.2-1) Three Phase - 

The normally closed (N/C) thermal 

sensor is embedded in the motor windings and will detect 
excessive heat in the event an overload condition occurs. The 
thermal sensor will trip when the windings become too hot and 
will automatically reset itself when the pump motor cools to a 
safe temperature. It is recommended that the thermal sensor 
be connected in series to an alarm device to alert the operator 
of an overload condition, and/or the motor starter coil to stop 
the pump. In the event of an overload, the source of this 
condition should be determined and rectifi ed immediately. 

DO 

NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD 
CONDITION OCCURS !

C-4.2-2) Single Phase -

 The type of in-winding overload 

protector used is referred to as an inherent overheating 
protector and operates on the combined effect of temperature 
and current. This means that the overload protector will trip out 
and shut the pump off if the windings become too hot, or the 
load current passing through them becomes too high. It will 
then automatically reset and start the pump up after the motor 
cools to a safe temperature. In the event of an overload, the 
source of this condition should be determined and rectifi ed 
immediately. 

DO NOT LET THE PUMP CYCLE OR RUN IF 

AN OVERLOAD CONDITION OCCURS !

C-4.3) Moisture Sensors:

A normally open (N/O) detector is installed in the pump 
seal chamber which will detect any moisture present. It is 
recommended that this detector be connected in series to an 
alarm device or the motor starter coil to alert the operator that 
a moisture detect has occurred. In the event of a moisture 
detect, check the individual moisture sensor probe leads for 

continuity, ( ∞  resistance = no moisture ) and the junction 
box/control box for moisture content. The above situations 
may induce a false signal in the moisture detecting circuit. If 
none of the above test prove conclusive, the pump(s) should 
be pulled and the source of the failure identifi ed and repaired. 

IF A MOISTURE DETECT HAS OCCURRED SCHEDULE 
MAINTENANCE AS SOON AS POSSIBLE.

If current through the temperature sensor exceeds the values 
listed, an intermediate control circuit relay must be used to 
reduce the current or the sensor will not work properly.

TEMPERATURE SENSOR ELECTRICAL RATINGS

Volts

Continuous

Amperes

Inrush

Amperes

220-240

1.50

15.0

440-480

0.75

7.5

575-600

0.60

6.0

C-4.4) Wire Size:

Consult a qualifi ed electrician for proper wire size if additional 
power cable is required. See table for electrical information.

SECTION: D START-UP OPERATION

D-1) Check Voltage and Phase:

Before operating pump, compare the voltage and phase 
information stamped on the pump identifi cation plate to the 
available power.

D-2) Check Pump Rotation:

Before putting pump into service for the fi rst time, the motor 
rotation must be checked. Improper motor rotation can result 
in poor pump performance and can damage the motor and/or 
pump. To check the rotation, suspend the pump freely, mo-
mentarily apply power and observe the “kickback”. “Kickback” 
should always be in a counter-clockwise direction as viewed 
from the top of the pump motor housing.

D-2.1) Incorrect Rotation for Three-Phase Pumps:

In the event that the rotation is incorrect for a three-phase 
installation, interchange any two power cable leads at the 
control box. 

DO NOT

 change leads in the cable housing in 

the motor. Recheck the “kickback” rotation again by momen-
tarily applying power.

D-2.2) Incorrect Rotation for Single-Phase Pumps:

In the unlikely event that the rotation is incorrect for a single 
phase pump, contact a CP&S Service Center.

D-3) Identifi cation Plate:

Record the numbers from the pump identifi cation plate for 
future reference.

D-3.1) Insulation Test:

Before the pump is put into service, an insulation (megger) 
test should be performed on the motor. The resistance values 
(ohms) as well as the voltage (volts) and current (amps) 
should be recorded.

D-3.2) Pump-Down Test

:

After the pump has been properly wired and lowered into the 
basin, sump or lift station, it is advisable to check the system 
by fi lling with liquid and allowing the pump to operate through 
its pumping cycle. The time needed to empty the system, or 
pump-down time along with the volume of water, should be 
recorded.

Summary of Contents for 4SE-L series

Page 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Brampton Piqua Ohio 45356 Ontario...

Page 2: ...RPM Fig 13 17 PARTS LIST 18 20 CROSS SECTION 3450RPM Fig 14 21 EXPLODED VIEW 3450RPM Fig 15 22 PARTS LIST 23 24 WARRANTY 25 RETURNED GOODS POLICY 26 WARRANTY REGISTRATION 26 SPECIAL TOOLS AND EQUIPMEN...

Page 3: ...OT insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safet...

Page 4: ...Magnet Wire Class F on selected models Service Factor 1 15 SINGLE PHASE Permanent Split Capacitor PSC Includes overload protection in motor THREE PHASE 200 230 460 60Hz is Tri voltage motor 575V Requ...

Page 5: ...Filled Squirrel Cage Induction Winding Class B Class H Rated Magnet Wire Service Factor 1 15 THREE PHASE Dual voltage 230 460 motor 575V Requires overload protection to be included in control panel VF...

Page 6: ...n or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage effluent or other nonexplosive or noncorrosive wastewater and shall NOT be installed in location...

Page 7: ...ads for continuity resistance no moisture and the junction box control box for moisture content The above situations may induce a false signal in the moisture detecting circuit If none of the above te...

Page 8: ...0 35 9 42 7 12 4 SOOW SOW 68 17 4 7 64 1 77 4SE2844L 2 8 460 3 60 1750 G B 4 0 21 3 14 4 SOOW SOW 57 14 5 10 64 4SE2854L 2 8 575 3 60 1750 F B 3 2 14 4 14 4 SOOW SOW 57 14 5 4 68 16 63 4SE3724L 3 7 23...

Page 9: ...l as per section F 1 4 F 1 3 Pressure Test Pumps that have had the oil drained from the Motor Housing Apply pipe sealant to pressure gauge assembly and tighten into pipe plug hole See Figure 2 Pressur...

Page 10: ...n oil from motor as outlined in paragraph F 1 2 Disassemble volute and impeller as outlined in paragraph F 2 1 and disassemble shaft seal as outlined in paragraph F 4 1 Position unit upright using blo...

Page 11: ...12 using connectors 11 and wire assemblies 12 as required Do not use wire nuts Slip motor leads and ground wire through fiberglass sleeve 10 Lower motor housing 2 down onto bearing bracket 21 while al...

Page 12: ...nge seal components replace the entire shaft seal 46 F 4 2 Reassembly Diaphragm At reassembly make sure the bulge and molded in part number of diaphragm 32 is facing the seal plate 25 With diaphragm 3...

Page 13: ...aragraph F 1 4 SECTION G REPLACEMENT PARTS G 1 ORDERING REPLACEMENT PARTS When ordering replacement parts ALWAYS furnish the follow ing information 1 Pump serial number and date code Paragraph G 4 2 P...

Page 14: ...14 FIGURE 11...

Page 15: ...security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always ood...

Page 16: ...16 61 60 52 53 15 3 26 34 35 19 20 24 28 9 44 43 47 30 29 58 59 2 1 46 33 56 55 54 57 10 27 18 16 14 39 25 21 42 32 48 49 OIL LEVEL 49 50 31 51 FIGURE 12 4SE 1150 1750RPM Pump Series...

Page 17: ...4 35 48 28 42 58 59 51 39 49 49 25 32 43 9 44 46 27 18 31 21 42 14 16 5 6 49 4 53 52 57 56 7 54 55 6 4 49 5 50 2 20 19 15 3 10 1 33 30 29 47 60 61 11 12 CONNECTOR ASSY 50 50 FIGURE 13 4SE 1150 1750RPM...

Page 18: ...se 4 6 026322 Lock washer 5 16 SS 5 2 014270 3 8 NPT Pipe Plug ZP 6 6 1 156 1 HXHD Cap Screw 5 16 18 x 1 LG SS 7 1 103503 Handle SS 9 4 20 13 1 1 4 Lock washer SS 10 2 625 02117 Fiberglass Sleeve 230V...

Page 19: ...D Cap Screw 1 4 20 x 1 LG SS 42 2 033730 t Square Ring Buna N 43 1 022879 Diaphragm Clamp Ring AI 44 4 002204 HXHD Cap Screw 1 4 20 x 1 LG Steel 4 1 7 1 HXHD Cap Screw 1 4 20 x 1 LG SS 46 1 064434 t S...

Page 20: ...103739XL 103586 4SE5044L 103742XC 103742XF 103742XL 103583 4SE5054L 103742XC 103742XF 103742XL 103583 MODEL NUMBER 30 FT SENSOR 50 FT SENSOR 100 FT SENSOR TERMINAL BLOCK SENSOR 4SE1926L 113288XC 1132...

Page 21: ...21 4SE L 3450RPM Pump Series FIGURE 14...

Page 22: ...2 63 26 24 34 35 28 42 58 59 51 39 25 32 43 9 44 46 27 18 21 42 14 16 5 47 29 30 33 1 12 10 11 60 61 19 20 2 5 7 4 6 57 56 55 54 53 52 4 6 49 49 50 50 31 49 49 48 49 50 FIGURE 15 4SE L 3450RPM Pump Se...

Page 23: ...105149A Jumper Wire 230V 3 Phase 13 150 oz 029034 Oil Motor Housing 40 oz 029034 Oil Seal Cavity 14 2 038156 Machine Screw 6 32 x 3 8 LG ZP 16 1 133403B Moisture Sensor Wire Red 1 133403A Moisture Sen...

Page 24: ...Cord Terminal Block 57 2 2 31051 224 O Ring Buna N 58 2 026989 Shim 005 Use as required 59 2 028120 Shim 010 Use as required 60 2 016660 Self Tap Screw 8 32 x 3 8 LG SS 61 1 105111 Ground Wire Sensor...

Page 25: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Page 26: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Reviews: