![background image](http://html1.mh-extra.com/html/baroness/fs900/fs900_service-manual_3907959039.webp)
Final tightening (Reset)
Fit the preliminary tightened tube onto the
fitting body. Tighten with a spanner to the
point where some resistance is suddenly felt,
then further tighten with the nut for a 1/4 turn.
w7s31b-009
Bite type tube fitting_009
Note:
For direct tightening, use the fitting body to
follow procedures 1 to 5 when using a
temporary tightening tool, and set the zero
point. Further tighten for 1 and 1/4 turn from
the zero point.
w7s31b-010
Bite type tube fitting_010
Reuse of piping
Bite type fitting can be reused if an inspection
finds no flaw or other damage on the sleeve
surface. Done properly, disassembly and
retightening can be carried out up to five
times or so.
Hydraulic system
FS900
Hydraulic system
Page 4-11
General instructions
Summary of Contents for FS900
Page 1: ...Riding Sweeper Service Manual Serial No FS900 10001 Ver 1 0...
Page 4: ...FS900 Contents...
Page 10: ...FS900 Safety Page 1 6 Safety Signs and Instruction Signs...
Page 11: ...Waste Disposal Page 2 2 About the Waste disposal Page 2 2 Disposal FS900 Disposal Page 2 1...
Page 28: ...FS900 Maintenance standards and maintenance Page 3 16 Greasing...
Page 74: ...FS900 Hydraulic system Page 4 46 Inspection and repair of each section...
Page 98: ...FS900 Electrical system Page 5 24 General inspection and repair...
Page 118: ...FS900 Main body Page 6 20 Inspection and repair of each section...