background image

 
 
 

 

Page 5/7 

 

Specifications 

 

IEEE Standards 

IEEE 802.3 10Base-T Ethernet 
IEEE 802.3u 100Base-TX Fast Ethernet 
IEEE 802.3x Flow Control and Back Pressure 

Switch Architecture 

Back-plane (Switching Fabric): 1Gbps  

Data Processing  

Store and Forward 

Flow Control 

IEEE 802.3x Flow Control and Back Pressure  

MAC address Table Size 

1K 

Packet Buffer Size 

448k 

Network Connector 

5xRJ-45 10/100/1000BaseT(X) auto negotiation,  
Auto MDI/MDI-X function, Full/Half duplex                 

Network Cable 

UTP/STP above Cat.5e Cable 

Protocol 

CSMA/CD 

LED 

PW1 (Green): ON

Power 1 is detected 

PW2 (Green): ON

Power 2 is detected  

TX/RJ-45 port:  
TX/RJ-45 port: 
LNK (Link/Active) (Green): ON

TX port is detected 

Flashing

TX data is transmitting/receiving 

Reserve polarity protection 

Present  

Overload current protection 

Present 

Power Supply 

Redundant Dual DC 12V-56V Power Input 

Power Consumption 

2.24W@48 VDC full load 

Removable Terminal Block 

Provide 1 power, 2 Pin 
Wire range: 0.34mm^2 to 2.5mm^2 
Solid wire (AWG):12-24/14-22 
Stranded wire(AWG): 12-24/14-22 
Torque:5lb-In/0.5Nm/0.56Nm 
Wire Strip length: 7-8mm 

Operating Temperature 

-40°C ~75°C   

Operating Humidity 

5% to 95% (Non-condensing) 

Storage Temperature 

-40°C ~85°C 

MTBF (mean time between failure) 

>500,000 hrs (Telcordia (Bellcore), GB) at 50°C 

Housing  

Rugged Aluminum, IP30 Protection 

Case Dimension (L x W x D) 

103.5 x 32 x 81.5 mm (L x W x D) 

Installation mounting  

DIN Rail and Wall Mount options included 

Summary of Contents for PC-IA100 Series

Page 1: ...User Manual PC IA500 Industrial Switch Version 5 2019 ...

Page 2: ...l mounted Din rail brackets and wall mounted brackets are included Power connection This unit comes with a 4 pin terminal block It can be operated from 12 56VDC power source Always make sure your input voltage is within this supported voltage range for each model WARNING Any exceeded input voltage will not make this unit function and may damage this unit To connect power This unit supports two pow...

Page 3: ...round screw STEP 3 Plug into terminal block socket shown above Polarity needs to match V and V WARNING Always SHUT OFF power source to connect power wire WARNING Always ground the power source to maintain a clean power input Cheaply made power supplies create too much noise and will cause the power input to fluctuate when connect to this unit To avoid this always ground the power source to maintai...

Page 4: ...Page 4 7 LED indicator ...

Page 5: ... TX RJ 45 port LNK Link Active Green ON TX port is detected Flashing TX data is transmitting receiving Reserve polarity protection Present Overload current protection Present Power Supply Redundant Dual DC 12V 56V Power Input Power Consumption 2 24W 48 VDC full load Removable Terminal Block Provide 1 power 2 Pin Wire range 0 34mm 2 to 2 5mm 2 Solid wire AWG 12 24 14 22 Stranded wire AWG 12 24 14 2...

Page 6: ...s Safety LVD EN60950 1 EMC CE FCC EN 55032 24 EMI CISPR 32 FCC Part 15B Class A EMS IEC 61000 4 2 ESD Contact 6KV Air 8KV IEC 61000 4 4 EFT Power 2KV Signal 2KV IEC 61000 4 5 Surge Power 2KV Signal 2KV Vibration EN 60068 2 6 ...

Page 7: ...Page 7 7 Housing Dimension mm ...